User manual
19 References
−173−
Parameter/operation data
OPX-2A screen
display
Name Setting range Initial value
− − − −
APP-1-02 Output signal selection 1
0: WNG output
1: MOVE output
2: MBC output
0
APP-1-08 Minimum ON time for MOVE signal 0 to 255 [ms] 5
− − − −
APP-1-02 Output signal selection 1
0: WNG output
1: MOVE output
2: MBC output
0
− − − −
− − − −
− − − −
SyS-0-02 Encoder output electronic gear A 1 to 1000 1
SyS-0-03 Encoder output electronic gear B 1 to 1000 1
APP-1-03 Output signal selection 2
0: ZSG2 output
1: NEAR output
0
APP-1-10 Alarm code output
0: Disable
1: Enable
0
− − − −
APP-2-07 Analog speed monitor maximum value 1 to 6000 [r/min] 5500
APP-2-08 Analog speed monitor maximum voltage 1 to 10 [V] 10
APP-2-09 Analog speed monitor offset voltage −1.00 to 1.00 [V] 0
− − − −
APP-2-10 Analog torque monitor maximum value 1 to 300 [%] 300
APP-2-11 Analog torque monitor maximum voltage 1 to 10 [V] 10
APP-2-12 Analog torque monitor offset voltage −1.00 to 1.00 [V] 0
APP-0-00 Gain tuning mode selection
0: Automatic
1: Semi-auto
2: Manual
0
APP-0-01 Load inertial moment ratio 0 to 10,000 [%] 500
− − − −
APP-4-00 Mechanical rigidity setting switch
0: Disable
1: Enable
1
APP-0-02 Mechanical rigidity setting 0 to 15 6