User manual
19 References
−179−
Parameter/operation data
OPX-2A screen
display
Name Setting range Initial value
APP-1-03 Output signal selection 2
0: ZSG2 output
1: ZV output
0
APP-1-06 Zero speed output band 1 to 5500 [r/min] 10
APP-1-10 Alarm code output
0: Disable
1: Enable
0
− − − −
APP-2-07 Analog speed monitor maximum value 1 to 6000 [r/min] 5500
APP-2-08 Analog speed monitor maximum voltage 1 to 10 [V] 10
APP-2-09 Analog speed monitor offset voltage −1.00 to 1.00 [V] 0
− − − −
APP-2-10 Analog torque monitor maximum value 1 to 300 [%] 300
APP-2-11 Analog torque monitor maximum voltage 1 to 10 [V] 10
APP-2-12 Analog torque monitor offset voltage −1.00 to 1.00 [V] 0
SyS-1-07 Data-setter initial display
0: Operating speed [r/min]
1: Position [steps]
2: Torque [%]
3: Estimated inertial moment ratio [%]
4: Operation number
5. Selected number
6: Tension [%]
7: Revolution counter [rev]
8: Roll diameter [mm]
9: Top screen of monitor mode
0