User manual

19 References
181
Parameter/operation data
OPX-2A screen
display
Name Setting range Initial value
SyS-1-03 Tension control mode selection
0: Simple
1: High function I
2: High function II
0
APP-2-04 Analog tension command gain 0 to 100 [%] 10
APP-2-05 Analog tension command offset voltage 1.00 to 1.00 [V] 0
APP-2-06 Analog input signal automatic offset
0: Disable
1: Enable
0
tEn Tension command 0 to 100 [%] 0
APP-2-00 Analog speed limit gain 0 to 5500 [r/min] 550
APP-2-01 Analog speed limit clamp 0 to 500 [r/min] 10
APP-2-02 Analog speed limit offset voltage 1.00 to 1.00 [V] 0
APP-2-06 Analog input signal automatic offset
0: Disable
1: Enable
0
rEv Speed limit 0 to 5500 [r/min] 0
dt Material thickness 1 to 5000 [µm] 50
din Initial diameter 1 to 1000 [mm] 500
dPK Final diameter 1 to 1000 [mm] 1000
JL Material inertial moment 0 to 99999.99 [× 10
4
kgm
2
] 0
Jc Core inertial moment 0 to 99999.99 [× 10
4
kgm
2
] 0
tEP Taper setting 0 to 100 [%] 100
SyS-1-04 Tension control gear ratio 1.0 to 1000.0 1.0
SyS-1-05 Analog input signals
0: Disable
1: Enable
1