User manual
7 Installation
−22−
• Motor frame size: 42 mm (1.65 in.)
Secure at the two mounting holes according to the installation method appropriate for your specific method of
use.
Installation method A
Pilot holder
Installation method B
Pilot holder
Motor type
Frame size
[mm (in.)]
Bolt size
Tightening torque
[N·m (oz-in)]
Effective depth of
bolt [mm (in.)]
Installation
method
6 (0.24) A
Standard 42 (1.65) M3 1 (142)
− B
• Motor frame size: 60 to 104 mm (2.36 to 4.09 in.)
Secure at the four mounting holes according to the installation method appropriate for your specific method
of use.
Installation method C
Pilot holder
Installation method D
Motor type
Frame size
[mm (in.)]
Bolt size
Tightening torque
[N·m (oz-in)]
Effective depth of
bolt [mm (in.)]
Installation
method
60 (2.36) M4 2 (280)
Standard
85 (3.35) M6 3 (420)
− D
60 (2.36) M5 2.5 (350) 10 (0.39)
PS geared
90 (3.54) M8 4 (560) 15 (0.59)
C
80 (3.15) M6 9 (1270)
PJ geared
104 (4.09) M8 15 (2100)
− D