7.3 Installing a load
When connecting a load to the motor, align the centers of the motor’s output shaft and load shaft. Be careful
not to damage the output shaft or the bearings (ball bearings) when installing a coupling or pulley to the
motors output shaft.
Installing on the flange surface
With a PJ geared type, a load can be installed directly to the gear using the load mounting holes provided on
the flange surface.
Load
Bolts
Flange
Metal plate
Load mounting holes
Motor
model
Bolt size
Number
of bolts
Tightening torque
[N·m (oz-in)]
Effective depth of
bolt [mm (in.)]
NXM810
NXM820
M6 6 9 (1270) 12 (0.47)
NXM1040
NXM1075
M8 6 15 (2100) 15 (0.59)
Electromagnetic brake motor
To release the electromagnetic brake and install the load, a DC power supply is needed to power the
electromagnetic brake. Use an extension cable for electromagnetic brake to connect a DC power supply of
24 VDC±10% to the motor.
Unit models come with an extension cable for electromagnetic brake.
24 VDC±10%
0.3 A or more
Black White
Varistor
Switch
Extension cable for
electromagnetic brake
Electromagnetic brake motor
DC power supply for
electromagnetic brake
To protect the switch contacts and prevent noise, the customer is advised to provide a varistor [recommended
varistor: Z15D121 (Ishizuka Electronics Corporation)].