User manual

7 Installation
24
7.4 Permissible overhung load and permissible thrust load
Permissible overhung load [N (lb.)]
Distance from the tip of motors output shaft [mm (in.)]
Type Unit model
0
(0)
5
(0.2)
10
(0.39)
15
(0.59)
20
(0.79)
25
(0.98)
30
(1.18)
35
(1.38)
Permissible
thrust load
[N (lb.)]
NX45
NX410
81
(18.2)
88
(19.8)
95
(21)
104
(23)
59 (13.2)
NX620
NX640
230
(51)
245
(55)
262
(58)
281
(63)
304
(68)
98 (22)
Standard
NX975
376
(84)
392
(88)
408
(91)
426
(95)
446
(100)
467
(105)
491
(110)
147 (33)
NX6-PS5
200
(45)
220
(49)
250
(56)
280
(63)
320
(72)
NX6-PS10
250
(56)
270
(60)
300
(67)
340
(76)
390
(87)
NX6-PS25
330
(74)
360
(81)
400
(90)
450
(101)
520
(117)
100 (22)
NX9-PS5
NX9-PS10
480
(108)
540
(121)
600
(135)
680
(153)
790
(177)
PS geared
NX9-PS25
850
(191)
940
(210)
1050
(230)
1190
(260)
1380
(310)
300 (67)
NX8-J5
300
(67)
330
(74)
350
(78)
380
(85)
400
(90)
430
(96)
460
(103)
500
(112)
300 (67)
NX8-J10
450
(101)
480
(108)
510
(114)
540
(121)
570
(128)
610
(137)
650
(146)
700
(157)
400 (90)
NX8-J25
680
(153)
710
(159)
750
(168)
780
(175)
840
(189)
900
(200)
950
(210)
1000
(220)
600 (135)
NX10-J5
650
(146)
700
(157)
730
(164)
750
(168)
800
(180)
830
(186)
880
(198)
920
(200)
500 (112)
NX10-J10
900
(200)
950
(210)
1000
(220)
1050
(230)
1100
(240)
1180
(260)
1230
(270)
1300
(290)
650 (146)
PJ geared
NX10-J25
1350
(300)
1400
(310)
1480
(330)
1550
(340)
1600
(360)
1650
(370)
1750
(390)
1850
(410)
1000 (220)
within the model name represents the output.
Permissible moment load of the PJ geared type
When installing an arm or table on the flange surface, calculate the moment load using the formula below if
the flange surface receives any eccentric load. The moment load should not exceed the permissible value
specified in the table.
Moment load: M [N·m (lb-in)] = F × L
Unit model
Permissible moment load
[N·m (lb-in)]
NX8-J5 16 (140)
NX8-J10 33 (290)
NX8-J25 60 (530)
NX10-J5 30 (260)
NX10-J10 66 (580)
NX10-J25 120 (1060)
within the model name represents the output.
L
F