Connector function table – Tension control mode
Pin
No.
Signal name Name
1
2 GND
Ground connection
3 ASG+
4 ASG
A-phase pulse line-driver output
5 BSG+
6 BSG
B-phase pulse line-driver output
7 ZSG1+
8 ZSG1
Z-phase pulse line-driver output
9 ALM+
10 ALM
Alarm output
11 WNG+/MOVE+
/MBC+
12 WNG/MOVE
/MBC
Warning output/ Motor moving output
/
Electromagnetic brake control signal output
13
14
15 READY+/AL0+
16 READY/AL0
Operation ready complete output/Alarm code output bit 0
17 VLC+/AL1+
18 VLC/AL1
Speed limit output/Alarm code output bit 1
19 ZSG2+/ZV+
/AL2+
20 ZSG2/ZV
/AL2
Z-phase pulse open-collector output/ Motor zero speed
output
/ Alarm code output bit 2
21 GND
Ground connection
22 IN-COM
Input common
23
24 ALM-RST Alarm reset input
25
26 W-RESET Roll diameter reset input
27 M0
28 M1
29 M2
Data selection input
30 FREE
Shaft free input
31 CW+
32 CW
CW input
33 CW+24 V CW input for 24 V
34 CCW+24 V CCW input for 24 V
35 CCW+
36 CCW
CCW input
The signal will become effective if the applicable setting has been changed using the data setter OPX-2A or the