10 Functions and operations in the speed control mode
72
STEP 2 Operate the motor
5. Confirm that the motor
rotates without problem.
3. Turn the BRAKE input ON.
4. Input the CW (CCW) signal.
To change the acceleration/
deceleration time: VR2
1. Set the control mode to
"Speed Control Mode."
Longer
acceleration/
deceleration
time
Shorter
acceleration/
deceleration
time
To change the speed
command value: VR1
Higher
speed
command
value
Lower
speed
command
value
SW1
2. Set the mechanical rigidity.
SW2
Note
The new settings of the control mode setting switches will become effective after the
power is cycled. If a 24 VDC power supply is used, also cycle the 24 VDC power supply.
STEP 3 Were you able to operate the motor properly?
How did it go? Were you able to operate the motor properly?
If the motor does not function, check the following points:
Is the BRAKE input ON?
Are the thermal terminals for regeneration resistor (TH1 and TH2) on the CN1 (shorted)?
Is any alarm present?
Are the power supply and motor connected securely?
Is the SPD LED (green) lit?
Isn’t the VR1 set to 0 r/min?
For more detailed settings and functions, refer to the following pages.
P.8 7