User manual

10 Functions and operations in the speed control mode
73
10.2 List of setting items
The items that can be set in the speed control mode are listed below.
You can use the data setter OPX-2A or the
data setting software MEXE02 to set
operation data or change the internal
parameters of the driver.
Parameter codes displayed on the OPX-2A
screen are shown in brackets. These codes are
also referenced in the main text herein. Use
these codes as keywords.
OPX-2A
MEXE02
For the method to set parameters with the OPX-2A or MEXE02, refer to the operating manual for each
option.
Operation data
Item Description
OPX-2A screen
display
Reference
Operating speed Sets the operating speed. rEv p.75
Torque limit Sets the torque limit value. trq p.84
Acceleration time Sets the acceleration time per 1000 r/min. tA p.75
Deceleration time Sets the deceleration time per 1000 r/min. td p.75
Application parameters
Item Description
OPX-2A screen
display
Reference
Gain tuning mode selection Selects the gain tuning mode. [APP-0-00]
Load inertial moment ratio Sets the ratio of load inertial moment and motor inertial moment. [APP-0-01]
Mechanical rigidity setting Selects the rigidity applicable to automatic, semi-auto or manual
tuning.
[APP-0-02]
Position loop gain Sets the position loop gain. When this value is increased, the
response will increase.
[APP-0-03]
Speed loop gain Sets the speed loop gain. When this value is increased, the
response will increase.
[APP-0-04]
Speed loop integral time
constant
Sets the speed loop integral time constant. When this value is
decreased, the response will increase.
[APP-0-05]
Speed feed-forward rate Sets the speed feed-forward rate. This parameter can be used to
shorten the positioning time.
[APP-0-06]
p.87
S-ON signal logic Changes the S-ON input logic. [APP-1-00] p.81
BRAKE signal logic Changes the BRAKE input logic. [APP-1-01] p.81
Output signal selection 1 Selects the output signal. [APP-1-02]
Output signal selection 2 Selects the output signal. [APP-1-03]
Zero speed output band Sets the output condition for ZV output. [APP-1-06] p.82
Attained speed output
band
Sets the output condition for VA output.
[APP-1-07] p.83
Minimum ON time for
MOVE signal
Sets the minimum ON time for MOVE output.
[APP-1-08] p.82
Alarm code output Changes the setting to enable/disable alarm code output. [APP-1-10] p.126
Analog speed command
gain
Sets the speed command per 1 V of analog input voltage.
[APP-2-00]
Analog speed command
clamp
Sets the speed at which to clamp the analog speed command to
zero.
[APP-2-01]
Analog speed command
offset voltage
Sets the offset voltage for analog speed command input.
[APP-2-02]
p.76
Analog torque limit gain Sets the torque limit per 1 V of analog input voltage. [APP-2-03]
Analog torque limit offset
voltage
Sets the offset voltage for analog torque limit input.
[APP-2-05]
p.85
Analog input signal
automatic offset
Changes the setting to enable/disable automatic offset for analog
input signals.
[APP-2-06] p.85