User manual
10 Functions and operations in the speed control mode
−73−
10.2 List of setting items
The items that can be set in the speed control mode are listed below.
You can use the data setter OPX-2A or the
data setting software MEXE02 to set
operation data or change the internal
parameters of the driver.
Parameter codes displayed on the OPX-2A
screen are shown in brackets. These codes are
also referenced in the main text herein. Use
these codes as keywords.
OPX-2A
MEXE02
For the method to set parameters with the OPX-2A or MEXE02, refer to the operating manual for each
option.
Operation data
Item Description
OPX-2A screen
display
Reference
Operating speed Sets the operating speed. rEv p.75
Torque limit Sets the torque limit value. trq p.84
Acceleration time Sets the acceleration time per 1000 r/min. tA p.75
Deceleration time Sets the deceleration time per 1000 r/min. td p.75
Application parameters
Item Description
OPX-2A screen
display
Reference
Gain tuning mode selection Selects the gain tuning mode. [APP-0-00]
Load inertial moment ratio Sets the ratio of load inertial moment and motor inertial moment. [APP-0-01]
Mechanical rigidity setting Selects the rigidity applicable to automatic, semi-auto or manual
tuning.
[APP-0-02]
Position loop gain Sets the position loop gain. When this value is increased, the
response will increase.
[APP-0-03]
Speed loop gain Sets the speed loop gain. When this value is increased, the
response will increase.
[APP-0-04]
Speed loop integral time
constant
Sets the speed loop integral time constant. When this value is
decreased, the response will increase.
[APP-0-05]
Speed feed-forward rate Sets the speed feed-forward rate. This parameter can be used to
shorten the positioning time.
[APP-0-06]
p.87
S-ON signal logic Changes the S-ON input logic. [APP-1-00] p.81
BRAKE signal logic Changes the BRAKE input logic. [APP-1-01] p.81
Output signal selection 1 Selects the output signal. [APP-1-02]
Output signal selection 2 Selects the output signal. [APP-1-03]
−
Zero speed output band Sets the output condition for ZV output. [APP-1-06] p.82
Attained speed output
band
Sets the output condition for VA output.
[APP-1-07] p.83
Minimum ON time for
MOVE signal
Sets the minimum ON time for MOVE output.
[APP-1-08] p.82
Alarm code output Changes the setting to enable/disable alarm code output. [APP-1-10] p.126
Analog speed command
gain
Sets the speed command per 1 V of analog input voltage.
[APP-2-00]
Analog speed command
clamp
Sets the speed at which to clamp the analog speed command to
zero.
[APP-2-01]
Analog speed command
offset voltage
Sets the offset voltage for analog speed command input.
[APP-2-02]
p.76
Analog torque limit gain Sets the torque limit per 1 V of analog input voltage. [APP-2-03]
Analog torque limit offset
voltage
Sets the offset voltage for analog torque limit input.
[APP-2-05]
p.85
Analog input signal
automatic offset
Changes the setting to enable/disable automatic offset for analog
input signals.
[APP-2-06] p.85