User manual

3 System configuration
8
3 System configuration
Driver
Connect to CN6.
PE
Connect to CN4.
Connect to CN7.
Connect
to CN2.
Connect to CN5.
Motor
Noise filter
Use a noise filter to eliminate noise.
It has the effect of reducing noise
generated from the power supply and driver.
Cable for encoder
This cable is used to connect the encoder and driver.
GND
24 VDC
Thermostat output
(AWG22) 2 pcs.
AWG20 for RGB200
Regeneration unit
An optional regeneration-unit (sold
separately). Connect this unit if
gravitational operation or other operations
involving up/down movement, or sudden
starting/stopping of a large inertial load,
will be repeated frequently.
24 VDC power supply
Be sure to connect a 24 VDC power
supply if the motor is equipped with
an electromagnetic brake.
Regeneration resistor
output (AWG18) 2 pcs.
Cable for motor
This cable is used to connect
the motor and driver.
Battery BAT01A
Connect this battery if you want
to operate the driver in the
position control mode using
the absolute system function.
Circuit breaker or ground
fault interrupt circuit (GFI)
Be sure to connect a circuit
breaker or ground fault
interrupt circuit to protect
the wiring on the primary side.
Power supply
Use the power supply within
the rated voltage range.
Single-phase 100-115 V
Single-phase 200-230 V
Three-phase 200-230 V
P.46
P.48, 62
P.1 2
P.2 7
P.43
P.31
P.4 5
P.4 8
P.138
P.138
P.31
P.4 2
P.32