Installation Manual

8
3A-3
3A-4
Step 3B Solid Concrete or Concrete Block Option
WARNING:
Ensure the wall plate is securely fastened to the wall before
continuing to the next step.
● Mount the wall plate [01] directly onto the concrete surface
● Anything covering the wall must not exceed 5/8 in. (16 mm)
● Minimum solid concrete thickness: 203 mm (8 in.)
● Minimum concrete block size: 203 x 203 x 406 mm (8 x 8 x 16 in.)
● Never drill into the mortar between blocks
Avoid potential personal injury or property damage! DO NOT over-tighten the
lag screws [F]. Tighten the lag screws [F] only until the washers [G] are pulled
firmly against the wall plate [01].
Wall
Anchor
O
7/32 in. (ø5.5mm)
2 9/16 in. (65mm)
Drill 4 pilot holes using a
7/32 in. (5.5mm) diameter
drill bit. Make sure the depth
is not less than 2 9/16 in.
(65mm)
Install the wall plate [01]
using lag screws [F] and
washers [G]. Tighten the lag
screws [F] only until the
washers [G] are pulled firmly
against the wall plate [01] .
1/2 in. (13mm)
Socket Wrench
(Not Included)
F
G