Dimensions

Because Whirlpool Corporation includes a continues commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10597144B
05/12/2016
Page 1 of 2
AGC6540KF
PRODUCT MODEL NUMBERS
30" (76.2 cm) Gas Built-In Cooktop
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural Gas:
This cooktop is factory set for use with Natural gas. If converting to
LP gas, see the “LP Gas Conversion” instructions provided in the
package containing literature. The model/serial rating plate located on
the underside of the cooktop base has information on the types of gas
that can be used. If the types of gas listed do not include the type of
gas available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas specified
on the model/serial rating plate for use with a different gas without
consulting the serving gas supplier. See the Gas Conversion instructions
provided in the package containing literature.
Gas Supply Line
Provide a gas supply line of
3
/
4
" (1.9 cm) rigid pipe to the cooktop
location. A smaller size pipe on longer runs may result in insufficient
gas supply. Pipe-joint compounds that resist the action of LP gas
must be used. Do not use TEFLON
®†
tape. With LP gas, piping
or tubing size should be
1
/
2
" minimum. Usually, LP gas suppliers
determine the size and materials used in the system.
Flexible metal appliance connector:
If local codes permit, use a
1
/
2
" or
3
/
4
" I.D. flexible stainless steel tubing
gas connector, designed by CSA to connect the cooktop to the rigid
gas supply line.
A
1
/
2
" male pipe thread is needed for connection to the female pipe
threads of the inlet to the cooktop pressure regulator.
Do not kink or damage the flexible metal tubing when moving the
cooktop.
Must include a shutoff valve:
The supply line must be equipped with a manual shutoff valve. This
valve should be located in the same room but external to the cooktop
opening, such as an adjacent cabinet. It must be accessible without
removing the cooktop, and it should be in a location that allows ease
of opening and closing. Do not block access to shutoff valve. The
valve is for turning on or shutting off gas to the cooktop.
A. Gas supply line
B. Shutoff valve “open” position
C. To cooktop
®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
ELECTRICAL REQUIREMENTS
A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this cooktop be
provided.
Electronic ignition systems operate within wide voltage limits, but
proper grounding and polarity are necessary. Check that the outlet
provides 120-volt power and is correctly grounded.
A
B
C
PRODUCT DIMENSIONS
A
B
C
D
E
F
G
A. 21" (53.3 cm)
B. 30" (76.2 cm)
C. 18
7
/
8
" (48.0 cm)
D. 28
3
/
8
" (72.1 cm)
E. 3
3
/
8
" (8.6 cm)
F. 4
1
/
2
" (10.5 cm)
G. 1
1
/
2
" (3.8 cm)