Installation Guide
7
Electrical Requirements
IMPORTANT: The cooktop must be electrically grounded in 
accordance with local codes and ordinances, or in the absence 
of local codes, with the National Electrical Code, ANSI/NFPA 70 
or Canadian Electrical Code, CSA C22.1.
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate.
A copy of the above code standards can be obtained from:
National Fire Protection Association 
One Batterymarch Park 
Quincy, MA 02269
CSA International 
8501 East Pleasant Valley Road 
Cleveland, Ohio 44131-5575
 ■ A 120-volt, 60 Hz, AC-only, 15-amp, fused electrical circuit
is required. A time-delay fuse or circuit breaker is also
recommended. It is recommended that a separate circuit
serving only this cooktop be provided.
 ■ Electronic ignition systems operate within wide voltage limits,
but proper grounding and polarity are necessary. Check that
the outlet provides 120-volt power and is correctly grounded.
 ■ The wiring diagrams are provided with this cooktop. See
“Wiring Diagrams” on a separate sheet. The wiring diagrams
are located on the left underside of the cooktop base.
Gas Supply Requirements
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes 
and ordinances. In the absence of local codes, installation must 
conform with American National Standard, National Fuel Gas 
Code ANSI Z223.1 - latest edition or CAN/CGA B149 - latest 
edition.
IMPORTANT: Leak testing of the cooktop must be conducted 
according to the manufacturer’s instructions.
Type of Gas
Natural Gas:
■ This cooktop is factory set for use with Natural gas.
If converting to propane gas, see the “Propane Gas 
Conversion” instructions provided in the package containing 
literature. The model/serial rating plate located on the 
underside of the cooktop base has information on the types 
of gas that can be used. If the types of gas listed do not 
include the type of gas available, check with the local gas 
supplier. 
Propane Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas 
specified on the model/serial rating plate for use with a different 
gas without consulting the serving gas supplier. See the Gas 
Conversion instructions provided in the package containing 
literature.
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to propane, have a qualified person make 
sure gas pressure does not exceed 14" (36 cm) water 
column. 
Examples of a qualified person include: 
licensed heating personnel, 
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.