AGC6540KF
PRODUCT MODEL NUMBERS
30" (76.2 cm) Gas Built-In Cooktop
GAS SUPPLY REQUIREMENTS
Type of Gas
Natural Gas:
 ■  This cooktop is factory set for use with Natural gas. If converting to 
LP gas, see the “LP Gas Conversion” instructions provided in the 
package containing literature. The model/serial rating plate located on 
the underside of the cooktop base has information on the types of gas 
that can be used. If the types of gas listed do not include the type of 
gas available, check with the local gas supplier.
LP Gas Conversion:
Conversion must be done by a qualified service technician.
No attempt shall be made to convert the cooktop from the gas specified 
on the model/serial rating plate for use with a different gas without 
consulting the serving gas supplier. See the Gas Conversion instructions 
provided in the package containing literature.
Gas Supply Line
 ■ Provide a gas supply line of 
3
/
4
" (1.9 cm) rigid pipe to the cooktop 
location. A smaller size pipe on longer runs may result in insufficient 
gas supply. Pipe-joint compounds that resist the action of LP gas 
must be used. Do not use TEFLON
®†
 tape. With LP gas, piping 
or tubing size should be 
1
/
2
" minimum. Usually, LP gas suppliers 
determine the size and materials used in the system.
Flexible metal appliance connector:
 ■ If local codes permit, use a 
1
/
2
" or 
3
/
4
" I.D. flexible stainless steel tubing 
gas connector, designed by CSA to connect the cooktop to the rigid 
gas supply line.
 ■ A 
1
/
2
" male pipe thread is needed for connection to the female pipe 
threads of the inlet to the cooktop pressure regulator.
 ■ Do not kink or damage the flexible metal tubing when moving the 
cooktop.
 ■  Must include a shutoff valve: 
The supply line must be equipped with a manual shutoff valve. This 
valve should be located in the same room but external to the cooktop 
opening, such as an adjacent cabinet. It must be accessible without 
removing the cooktop, and it should be in a location that allows ease 
of opening and closing. Do not block access to shutoff valve. The 
valve is for turning on or shutting off gas to the cooktop.
A.  Gas supply line
B.  Shutoff valve “open” position
C.  To cooktop
†
®
TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
ELECTRICAL REQUIREMENTS
 ■ A 120 volt, 60 Hz, AC only, 15-amp, fused electrical circuit is required. 
A time-delay fuse or circuit breaker is also recommended. It is 
recommended that a separate circuit serving only this cooktop be 
provided.
 ■ Electronic ignition systems operate within wide voltage limits, but 
proper grounding and polarity are necessary. Check that the outlet 
provides 120-volt power and is correctly grounded.
A
B
C
PRODUCT DIMENSIONS
A
B
C
D
E
F
G
A.  21" (53.3 cm)
B.  30" (76.2 cm)
C. 18
7
/
8
" (48.0 cm)
D. 28
3
/
8
" (72.1 cm)
E. 3
3
/
8
" (8.6 cm)
F.  4
1
/
2
" (10.5 cm)
G. 1
1
/
2
" (3.8 cm)