Dimension Guide

PRODUCT MODEL NUMBERS
Because Whirlpool Corporation includes a continuous commitment to improve our
products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Page 1 of 2
Ref. W10860789A
12/19/16
AGR5330BA
30"(76.2 cm) Freestanding Gas Ranges
PRODUCT DIMENSIONS
A. 36" (91.4 cm)
B. 29
7
8
" (75.9 cm)
C. 25
7
64
" (63.8 cm)
D. 47
5
64
" (119.6 cm)
B
A
C
D
ELECTRICAL REQUIREMENTS
A 120-volt, 60 Hz., AC-only, 15-amp fused, electrical circuit is required.
A time-delay fuse or circuit breaker is also recommended. It is
recommended that a separate circuit serving only this range be provided.
GAS REQUIREMENTS
Observe all governing codes and ordinances.
IMPORTANT: This installation must conform with all local codes and
ordinances. In the absence of local codes, installation must conform
with American National Standard, National Fuel Gas Code ANSI Z223.1 -
latest edition or CAN/CGA B149 - latest edition.
IMPORTANT: Leak testing of the range must be conducted according
to the manufacturer’s instructions. See “Complete Connection” in the
“Make Gas Connection” section.
Type of Gas
Natural gas:
This range is factory set for use with Natural gas. The model/serial
rating plate located on the left side of the bottom of the broiler has
information on the types of gas that can be used. If the types of gas
listed do not include the type of gas available, check with the local gas
supplier.
LP gas conversion:
Conversion must be done by a qualified service technician. No attempt
shall be made to convert the appliance from the gas specified on the
model/serial rating plate for use with a different gas without consulting
the serving gas supplier. See “Gas Conversions” section.
Gas Supply Line
Provide a gas supply line of
3
/
4
" (1.9 cm) rigid pipe to the range
location. A smaller size pipe on longer runs may result in insufficient
gas supply. With LP gas, piping or tubing size can be
1
/
2
" (1.3 cm)
minimum. Usually, LP gas suppliers determine the size and materials
used in the system.
NOTE: Pipe-joint compounds that resist the action of LP gas must be
used. Do not use TEFLON
®†
tape.
Flexible metal appliance connector:
If local codes permit, a new CSA design-certified, 4 to 5 ft (122
to 152.4 cm) long,
1
/
2
" (1.3 cm) or
3
/
4
" (1.9 cm) I.D., flexible metal
appliance connector may be used for connecting range to the gas
supply line.
A
1
/
2
" (1.3 cm) male pipe thread is needed for connection to the
female pipe threads of the inlet to the appliance pressure regulator.
Do not kink or damage the flexible metal tubing when moving the
range.
Must include a shut-off valve:
The supply line must be equipped with a manual shut-off valve. This
valve should be located in the same room but external to the range
opening, such as an adjacent cabinet. It should be in a location that
allows ease of opening and closing. Do not block access to shut-off
valve. The valve is for turning on or shutting off gas to the range.
A. Gas supply line
B. Shut-off valve “open” position
C. To range
A
B
C

Summary of content (2 pages)