TECHNICAL INFORMATION MANUAL AMV8 39" 80% Gas Furnace Upflow/Horizontal Models listed on page 3. • Refer to RS6610004 Service Manual for installation, operation, and troubleshooting information. • All safety information must be followed as provided in the Service Manual. • Refer to the appropriate Parts Catalog for part number information. ® C This manual is to be used by qualified, professionally trained HVAC technicians only.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information.
PRODUCT IDENTIFICATION The model and manufacturing number are used for positive identification of component parts used in manufacturing. Please use these numbers when requesting service or parts information. AMV80704BX** AMV80905CX** AMV81155CX** WARNING The United States Environmental Protection Agency (“EPA”) has issued various regulations regarding the introduction and disposal of refrigerants introduced into this unit.
PRODUCT DESIGN General Operation Notes: AMV8 furnaces are equipped with an electronic ignition device used to light the burners and an induced draft blower to exhaust combustion products. 1. Category I Venting is venting at a non-positive pressure. A furnace vented as Category I is considered a fan-assisted appliance and the vent system does not have to be “gas tight.” An interlock switch prevents furnace operation if the blower door is not in place.
PRODUCT DESIGN Accessibility Clearances (Minimum) High Altitude Derate Unobstructed front clearanace of 24" for servicing is recommended. When this furnace is installed at high altitude, the appropriate High Altitude orifice kit must be installed. This is required due to the natural reduction in the density of both the gas fuel and combustion air as altitude increases. The kit will provide the proper design certified input rate within the specified altitude range.
COMPONENT IDENTIFICATION Primary Limit Pressure Switch Flue Pipe Connection Gas Line Entrance (Alternate) Gas Line Entrance Induced Draft Blower Rollout Limit Inshot Burner Gas Manifold Circulator Blower Junction Box Transformer Integrated Control Module Upflow/Horizontal 1 Gas Valve 10 Induced Draft Blower 2 Gas Line Entrance (Alternate) 11 Blower Door Interlock Switch 3 Pressure Switch(es) 12 Integrated Control Module 4 Gas Manifold 5 Rollout Limit 13 Transformer (40 VA) 7 Primary Limi
PRODUCT DIMENSIONS AMV8*****XA Alt. Vent Location Alt. Vent Location Alt. Gas Inlet Alt.
PRODUCT DESIGN PRESSURE SWITCH TRIP POINTS AND USAGE CHART 0 to 8,000 ft. MODEL Negative Pressure ID Blower With ID BLOWER Flue not Firing PRESSURE typical Sea SWITCH (1) PART # Level Data LOW FIRE HIGH FIRE AMV80704BX** -0.30 -0.45 B1370208 AMV80905CX** -0.30 -0.50 B1370209 AMV81155CX** -0.30 -0.55 B1370210 Note: All negative pressure readings are in inches of water column (" w.c.). (1) Data given is least negative pressure required for pressure switch to close. T.O.D.
PRODUCT DESIGN Coil Matches: A large array of Amana® brand coils are available for use with the new AMV8 furnaces, in either upflow or horizontal applications. These coils are available in both cased and uncased models, with or without a TXV expansion device. These 80% furnaces match up with the existing Amana® brand coils as shown in the chart below.
PRODUCT DESIGN Thermostats: The following Amana® brand Thermostats are suggested for use with the AMV8 Furnace Models: Two-Stage Thermostat Description Thermostat Programmable Cool Heat Hard Wired Battery Powered 1213411 No 2 2 Yes Yes 1213407 Yes 1 2 Yes Yes 1213406* Yes 2 3 Yes No * For use in dual-fuel applications with a heat pump in a fossil fuel application. It is not for use with the AMV8 as a sole heating source.
FURNACE SPECIFICATIONS MODEL AMV80704BX** AMV80905CX** AMV81155CX** 70,000 90,000 115,000 Output (US) High Fire (Natural Gas), BTUH 57,000 74,000 93,000 Output (US) High Fire (LP), BTUH 49,000 64,000 82,000 Btuh Input (US) Low Fire (Natural Gas) 52,500 67,500 86,000 Output (US) Low Fire (Natural Gas), BTUH 42,000 54,000 69,000 Output (US) Low Fire (LP), BTUH 42,000 54,000 69,000 80% 80% 80% Rated External Static (" w.c.) .20 - .50 .20 - .50 .20 - .
BLOWER PERFORMANCE SPECIFICATIONS High or Single-Stage Cooling Speeds AMV80704BX** Cooling Speed Tap A B C D AMV80905CX** Adjust Tap CFM @ .1" to .8" W.C. ESP Minus (-) Tap 540 Cooling Speed Tap A AMV81155CX** Adjust Tap CFM @ .1" to .8" W.C. ESP Minus (-) Tap 720 Cooling Speed Tap A Adjust Tap CFM @ .1" to .8" W.C.
BLOWER PERFORMANCE SPECIFICATIONS Cooling-Based Continuous Fan AMV80704BX** Cooling Speed Tap A B C D Adjust Tap AMV80905CX** CFM @ .1" to .8" W.C. ESP Minus (-) Tap 361** Nominal 361** Cooling Speed Tap A Adjust Tap AMV81155CX** CFM @ .1" to .8" W.C. ESP Minus (-) Tap 563** Nominal 563** Cooling Speed Tap A Adjust Tap CFM @ .1" to .8" W.C.
BLOWER PERFORMANCE SPECIFICATIONS AMV80704BX** (Rise Range 20 - 50 °F) Heating Speed Tap A B C D Adjust Tap Low Stage CFM @ .1" to .5" w.c. ESP High Stage CFM @ .1" to .5" w.c.
TEMPERATURE RISE 10 20 30 40 30 50 60 70 80 90 100 40 50 60 700 600 CFM 90 100 2000 2200 2400 CFM 1800 1600 1400 OUTPUT BTU/HR x 1000 80 1200 1100 1000 900 70 800 FORMULAS 110 120 130 140 BTU OUTPUT = CFM x 1.08 x RISE BTU OUTPUT RISE = ÷ CFM 1.
WIRING DIAGRAMS AMV8 HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. Wiring is subject to change, always refer to the wiring diagram on the unit for the most up-to-date wiring.
SCHEMATICS HIGH VOLTAGE! DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. ELECTRONIC AIR CLEANER INDUCER EAC EAC NEU IND IND IND HI LO NEU HUM HUMIDIFIER 13 ENABLE LOW HEAT HI HEAT 16 PIN VARIABLE SPD MOTOR CONNECTOR 2 C. CIR U NE CIRC. HOT 15 HUMN TRANSISITOR LOGIC MVH R TRANSISITOR LOGIC W9 G BK W10 TH HEAT CIRC. REQUEST FROM MICRO XFMR .24 V.A.C XFMRN .