Service manual

Component Testing Information
!
WARNING
To avoid risk of electrical shock, personal injury, or death, disconnect power to oven before servicing, unless
testing requires it.
RS2310005 Rev. 011
General Component Test Procedure Results
3-wire power cord Check for continuity Verify polarity and grounding.
Oven light socket Remove one wire from receptacle
and test resistance of terminals........
Measure voltage at oven light. .........
Indicates continuity with bulb screwed in.
120 VAC, see wiring diagram for terminal
identification.
If no voltage is present at oven light,
check wiring or light switches.
Auto latch assembly Motor switch
Unlocked.....................................
Locked........................................
Door switch
Door closed.................................
Door open...................................
COM
−
N.O.
continuity
COM
−
N.O.
open
COM
−
N.C.
continuity
COM
−
N.C.
open
Pressure regulator
with shut-off valve
Verify gas pressure (WCP).
If on LP service verify proper gas
supply conversion.
6
"
Natural
10
"
LP/propane
WARNING
!
To avoid risk of fire, always test for leaks
after a gas component repair.
Gas valve Disconnect wiring to valve.
Measure resistance on bake circuit.
Measure resistance on broil circuit.
Continuity.
If not, replace.
Continuity.
If not, replace.
WARNING
!
Do not attempt to open valve with
120 VAC.
Ignitor Test for voltage at terminals.............
Test for the amount of amperage in
the circuit. ........................................
(Ignitor may glow but not have
sufficient amperage to open valve).
120 VAC
3.2
−
3.6 Amps.
270
°
valve
Verify gas is supplied.
Orifice adjusted for Natural or LP.
Adjust set screw for simmer control.
Spark 270
°
switch Test for voltage at terminals.............
Disconnect wiring and check for
continuity in LITE position. ...............
120 VAC
Continuity in LITE position.
Spark ignition
electrode
Test for resistance of spark lead. .....
Test ignitor to chassis. .....................
Continuity
No continuity from ignitor to chassis.
Top surface burner Verify gas is supplied.
Verify burner cap is positioned
correctly, clean and free of debris.
Check for obstructions in burner
ports.
Check for continuity to chassis......... Continuity