Service manual

RS2310005 Rev. 0 A–2
LP/Propane
Conversion
Converting for Use with
LP/Propane Gas
Your range is factory set for use with natural gas. If LP/Propane gas use is
desired, the range must be converted. Gas supply should be turned off
prior to conversion.
Converting Pressure Regulator for Use with
LP/Propane
1. Remove storage drawer from front of range.
Refer to
Removing Storage Drawer
section in Owner’s Manual.
2. Locate pressure regulator.
3. Remove the pressure regulator cap with a wrench.
4. Pull plastic insert from pressure regulator cap.
• Plastic insert is placed tightly in cap.
• Pliers or a wrench may be used to carefully remove the insert.
5. Reverse plastic insert and carefully push
plastic insert firmly into hole in pressure
regulator cap.
• Insert stem must show LP rightside up.
• Long end of insert should be inserted into
cap as shown.
6. Place pressure regulator cap on pressure
regulator and tighten.
• Insert should not disturb
spring in body of regulator.
7. Verify regulator shutoff valve
is in OPEN position.
8. Replace storage drawer.
Refer to Owners Manual and Installation
Instructions for safety statements.
Keep these instructions for future reference.
Installation must conform to all local,
municipal and state building codes and
local utility regulations.
pressure
r
egulator cap
plastic
insert
spring location
LP
Questions?
Refer to Owners Manual
or call Amana Consumer Affairs Department
1-800-843-0304
oven shutoff valve
OPEN position
WARNING
!
To avoid electric shock that can
cause personal injury or death,
disconnect main electrical supply
to range before servicing.