Service manual

RS2310005 Rev. 0 A–4
Converting Pressure Regulator for Use with
Natural Gas
1. Remove storage drawer.
• Refer to
Removing Storage Drawer
section in Owner’s Manual.
2. Locate pressure regulator.
3. Remove pressure regulator cap with a
wrench.
4. Remove plastic insert from pressure regulator cap.
• Plastic insert fits tightly in cap.
5. Reverse plastic insert and carefully push plastic
insert firmly into hole in pressure regulator cap.
• Insert must show NAT rightside up or be blank.
6. Place pressure regulator cap on pressure
regulator and tighten.
• Insert should not disturb spring in body of
regulator.
7. Verify that pressure regulator supply valve is in
OPEN position
8. Replace storage drawer.
Refer to Owners Manual and Installation
Instructions for safety statements.
Reconverting for Use with Natural Gas
This range is shipped from the factory for use with natural gas. Range
needs to be converted for use to natural gas only if it has been converted for
use with LP/Propane after leaving the factory. Gas supply should be turned