Service manual

A–5 RS2310005 Rev. 0
Converting Broiler Burner for Use with Natural Gas
Converting Surface Burners for Use with Natural Gas
1. Remove the 4 burner control knobs from range.
• 2 screws are exposed on burner control panel.
2. Remove 2 screws from burner control panel.
• Panel drops slightly after screws are removed.
3. Grasp bottom of burner control panel, gently lift and pull
out panel until clear of burner valve stems.
• After burner control panel clears valve stems, continue
to roll panel until free from range. Set aside.
• Gas valve and orifice hood are visible after burner
control panel are removed.
4. While facing range front, turn orifice hoods clockwise
1½ to 2 turns.
• A mark may be placed on the orifice hood so turns can
be easily counted.
• Use ½ inch open end or 90° offset open end wrench.
5. Adjust airflow to burner flame by adjusting air shutter
to
1
/
4
" opening.
• Refer to
Adjusting Surface Burner Flame
section in Owner’s Manual.
6. Reassemble burner control panel after adjusting air flow to surface burner flame.
2000 Amana Appliances
Amana, Iowa 52204
Part No. 36-32025201-0
Printed in U.S.A. 11/00
burner knob
p
ivot
p
oint
orifice hood
air shutter
orifice
hood
air
shutter
orifice
hood
1. Open the oven door and locate the broiler burner on oven ceiling.
2. Locate the orifice spud on the broiler fitting in the back of the oven.
3. Using a
1
/
2
" open end wrench turn the orifice hood counterclockwise
1 to 1
1
/2 turns.
• A mark may be placed on the orifice hood so turns can be easily
counted.
• Do not over tighten orifice hoods. If orifice hoods are over
tightened, gas supply can be cutoff or orifice hoods can strip.
4. Close the oven door.
• Air flow may need to be adjusted to oven burner flame after
conversion. Refer to Owner’s Manual for instructions.
Converting Oven Burner for Use with Natural Gas
1. Remove storage drawer.
• Refer to
Removing Storage Drawer
section in Owner’s Manual.
2. Locate the bake burner orifice hood.
3. Using a
1
/
2
" open end wrench turn the orifice
hood counterclockwise 2 turns.
• A mark may be placed on the orifice
hood so turns can be easily counted.
• Do not over tighten orifice hoods. If
orifice hoods are over tightened, gas supply
can be cutoff or orifice hoods can strip.
4. Verify fuel supply shut off valve is in OPEN
position.
5. Replace storage drawer.
• Air flow may need to be adjusted to oven burner flame after