Product SPecificationS: PtH ModelS — cooling/Heat PuMP/electric Heat

,
,
,
9

**AXXX

**AXXX

**AXXX

**AXXX

**AXXX

**AXXX

**AXXX

**AXXX
Voltage ¹
,
³ 230 / 208 230 / 208 230 / 208 230 / 208 265 265 265 265
Capacity (BTU/h) 7,600 9,000 12,000 14,200 7,600 9,100 12,000 14,200
Amps ¹⁰ 3.9 4.2 5.8 7.0 3.1 3.7 5.0 6.1
Was ¹⁰ 650 785 1,125 / 1,100 1,465 / 1,445 650 790 1,120 1,465
EER 11.7 11.5 10.7 9.7 11.7 11.5 10.7 9.7

Min. Circuit Amps ²
,
,
¹⁰ 4.7 5.1 7.1 8.5 3.8 4.5 6.1 7.4
CFM (Cool/Wet Coil)
High 340 330 340 390 340 330 340 390
Low 245 245 245 340 245 245 245 340
CFM (Dry Coil)
High 370 360 370 410 370 360 370 410
Low 270 270 270 370 270 270 270 370
Venlated Air, CFM (Fan Only)* 65* 65* 65* 65* 65* 65* 65* 65*
Venlated Air, CFM (Comp & Fan)* 40* 40* 40* 40* 40* 40* 40* 40*
Dehumidicaon (Pints/Hr.) 1.7 2.2 3.6 4.4 1.7 2.2 3.6 4.4
Net Weight (lbs.) 108 112 115 126 108 112 115 125
Ship Weight (lbs.) 123 127 132 143 123 127 132 142
* Actual vent CFM performance will vary due to applicaon and installaon condions.

¹ All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit (PTPWHWK4).
² Minimum Circuit Ampacity (MCA) rangs conform to the Naonal Electric Code; however, local codes should apply.
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts.
³ Minimum voltage on 265-volt models is 239 volts; maximum is 292 volts.
⁴ Overcurrent protecon for all units without electric heaters is 15 amps. Overcurrent protecon on 265-volt models must be cartridge-style me-delay
fuses (included and factory-installed on all Amana® brand 265-volt chassis).
⁵ Heang capacity and eciency based on unit operaon without condensate pump; unit automacally switches to electric heat at approximately 24°F
outdoor ambient.
⁶ Specify two-digit heater kW size to complete model number.
⁷ R-410A refrigerant used in all systems.
⁸ All units meet or exceed ASHRAE 90.1 standards.
⁹ All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
¹⁰ Refer to electric heat performance data for total MCA and recommended overcurrent protecon. Amps and Was notaon refers to compressor only.