Specifications

WIRING DIAGRAMS
TO AVOID POSSIBLE ELECTRICAL SHOCK, PERSONAL INJURY,
OR DEATH, DISCONNECT THE POWER BEFORE SERVICING.
WARNING
!
105 Rev. 3
YL YELLOW
OR ORANGE
VT VIOLET
GN GREEN
BK BLACK
BR BROWN
WH WHITE
BU BLUE
GY GRAY
RD RED
COLOR CODE
LOW VOLTAGE
LOW VOLTAGE FIELD
HI VOLTAGE
HI VOLTAGE FIELD
HEATING BLOWER SPEEDFURNACE MODEL
MOTOR TO "HEAT"
GDC: 045X30*
FACTORY WIRED BLOWER MOTOR TO CONTROL CONNECTIONS
COOLING
BLOWER SPEED
SEE
INSTALLATION
INSTRUCTIONS
TO DETERMINE
PROPER
COO LING
BLOWER SPEED.
3
MOTOR
SPEEDS
LOW
SPEED
GDC: 070X30*
IMPORTANT:
4. UNUSED BLOWER MOTOR LEADS MUST BE PLACED ON "PARK" TERMINALS OF CONTROL OR TAPED.
READ BEFORE OPERATING OR SERVICING THIS UNIT.
1. SET HEAT ANTICIPATOR ON ROOM THERMOSTAT AT 0.7 AMPS.
2. AMANA SPECIFIED REPLACEMENT PARTS MUST BE USED WHEN SERVICING.
3. IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE FURNACE MUST BE
REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST
105°C. USE COPPER CONDUCTORS ONLY.
5 IF HEATING AND COOLING BLOWER SPEEDS ARE NOT THE SAME DISCARD JUMPER
BEFORE CONNECTING
BLOWER LEADS.
RD-24
HI BK-26 4
*
**
6 DIAGNOSTIC LIGHT:STEADY=REPLACE CONTROL;1 FLASH=LOCKOUT;2 FLASHES=PS STUCK CLOSED;
3 FLASHES=PS STUCK OPEN;4 FLASHES=OPEN LIMIT SWITCH;5 FLASHES=OPEN RO
LLOUT CONTROL;
CONTINUOUS FLASHING=FLAME-NO CALL FOR HEAT
11173201 REV. 1
BR-21
PRIMARY
ROLLOUT
LIMIT (RL)
FLAME SENSOR
COMBUSTIO N
BLOWER
(CB)
DOOR SWITCH (CLOSED
WHEN DOOR IN PLACE)
115V
FIELD
CONNECT
AIR
CIRCULATION
BLOWER
(ACB)
CAPACITOR
(CAP)
BR
BR
X
F
M
R
I
G
N
I
N
D
C
O
O
L
H
E
A
T
P
A
R
K
P
A
R
K
L
I
N
E
X
F
M
R
L
I
N
E
C
I
R
WY
LOAD
LINE
TRANSFORMER
#29 OR (MED LOW)
#26 BK (HI)
#23 BU (MED)
#24 RD (LOW)
COVER PRESSURE
SWITCH (PS2)
NC
NO
COM
**
*
CONTROL
RD-22
BK-6
BK-3
WH
BK
GY-47
BU-15
OR
-18
YL
-11
OR-16
BU-25
BK-1
WH-2
12
14710
11852
369
BR-21
BU
-36
GY
-25
BK-6
BK-1
VT
-55
RD
-22
OR-3
BU-17
BU-36
VT
-55
5
6
GAS
VALVE
(GV)
THERMOSTAT
CONNECTIONS
WARNING:DISCONNECT POWER BEFORE
SERVICING.WIRING TO UNIT MUST BE
PROPERLY POLARIZED AND GROUNDED.
WARNING:DISCONNECT POWER
BEFORE SERVICING.WIRING TO
UNIT MUST BE PROPERLY
POLARIZED AND GROUNDED.
IGNITOR
WH-
23
WH-33
WH
GND
N
L1
RGC
ELECTRICAL BOX
3
2
1
H
U
M
E
A
C
H
U
M
E
A
C
115V FIELD
CONNECT
HUMIDIFIER
115V FIELD
CONNECT
ELECTRONIC
AIR CLEANER
HOT 120VAC
NEUTRAL 120VAC
CIRCULATOR BLOWER
TH FP
HLO
RO1
TR
MV
GND
HLI
PS
RO2
MV
GDC: 070X40*
090X40*
090X50*
115X50*
P
C
M
WH
GY-47
BU-25
GY-25
OR-3
RD-44
RD-44
GN
GN
PRIMARY
RL
N
L1
DOOR
SWITCH
GND
IGNITOR
GV
CB
PS1
NO
C
I
N
D
L
I
N
E
N
E
U
120 V
TRANS-
FORMER
24 V
S
E
N
S
O
R
CAP
ACB
Y
W
THERMOSTAT
CONNECTIONS
CONTROL
6
5
TERMINAL ORDER REARRANGED FOR CLARITY
A
U
X
L
I
M
I
T
**
*
F
L
A
M
E
R
G
C
C
NC
NO
E
A
C
H
O
T
E
A
C
N
E
U
H
U
M
H
O
T
H
U
M
N
E
U
L
I
N
E
H
O
T
X
F
M
R
H
O
T
X
F
M
R
N
E
U
T
H
P
S
H
L
I
H
L
O
M
V
M
V
V
C
O
O
L
H
E
A
T
P
A
R
K
P
A
R
K
C
I
R
N
E
U
I
G
N
F
P
G
N
D
T
R
R
0
2
R
0
1
L
I
M
I
T
RD
-44
RD
-44
* MANUFACTURER'S
VARIABL E LETTER
MED 4BU-23
NC
NO
COM
OR-16
PS2
C
NC
NO
COMBUSTION PRESSURE
SWITCH (PS1)
AUX LIMIT
CONTROL
PRIMARY
LIMIT
VT-14
YL-11
VT
-14