APg15 PACkAged gAS/eleCTriC
The Amana® brand APG15 Packaged Gas/Electric unit uses the chlorine-free refrigerant R-410A and provides high-efciency
performance. This unit is housed in a heavy-gauge, zinc-coated steel cabinet with a weather-resistant, powder-paint nish and
allows for a ground-level or rooftop mount, horizontal or downow application.
W” D”
APG152407041A 2 69,000 208/230-1 47 51 34¾ 76 439
APG153009041A 2½ 92,000 208/230-1 47 51 34¾ 76 475
APG153609041A 3 92,000 208/230-1 47 51 34¾ 76 480
APG153709041A 3 92,000 208/230-1 47 51 34¾ 76 480
APG154211541A 3½ 115,000 208/230-1 47 51 42¾ 78 560
APG154811541A 4 115,000 208/230-1 47 51 42¾ 78 560
APG154911541A 4 115,000 208/230-1 47 51 42¾ 78 560
APG156014041A 5 138,000 208/230-1 47 51 42¾ 78 565
Goodman Company, L.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations.
* Complete warranty details available from your local dealer or at www.amana-
hac.com. To receive the Lifetime Heat Exchanger Limited Warranty and
Lifetime Compressor Limited Warranty (in each case good for as long as you
own your home) plus the 10-Year Parts Limited Warranty, online registration
must be completed within 60 days of installation. Online registration is not
required in California or Quebec.
ENERGY STAR ratings are dependent upon conditions beyond
equipment installation. To make certain your HVAC equipment
qualies for the ENERGY STAR designation, get complete
information at www.energystar.gov.
Product FeatureS
• Heavy-duty Million-Air® stainless-steel
dual-diameter, tubular heat exchanger
• Up To 15 SEER/80% AFUE
• High-efciency compressor with factory-installed sound cover;
two-stage compressor on 4- and 5-ton models
• EEM (energy-efcient) blower motor
• Fully-charged R-410A refrigerant system
• Copper tube/aluminum n coils
• Redundant two-stage gas valve; natural gas with easy conversion
to propane
• Power-assisted combustion
• Direct-spark ignition system, including a microprocessor-based control
for the entire ignition sequence
• All blower operation and all safety circuits complete with self-diagnostics
• Loss-of-charge protection and high-pressure switch
• All models comply with California NOx emission standards
• AHRI Certied; ETL Listed
• Fully insulated, heavy-gauge, zinc-coated steel cabinet
with UV-resistant powder-paint nish
• Fits in a standard-size pick-up truck
• One roof curb ts all units
• Convenient access panels
• Bottom 2” high base rails for easier handling