Unit installation

15
Turn the unit on at the thermostat. Wait a few minutes, since
any dislodged dust will alter the normal flame appearance.
Flames should be predominantly blue and directed into the
tubes. They should not be yellow. They should extend
directly outward from the burner ports without curling down-
ward, floating or lifting off the ports.
XIII. Accessories and Functional Parts
SHEET METAL ACCESSORIES
Additional Amana accessories, as described in Table 4, can
be purchased to fit specific application needs. Accessories
can be ordered by the part numbers in the table and each
accessory includes its own separate instructions.
Accessory
Duct Transition Over/Under
Horizontal Duct Covers*
Compressor Sound Blanket
Horizontal Filter Kit
Propane Gas Conversion Kit
High Altitude Kit
* Standard on PGA**C
Table 4
Accessory List
FUNCTIONAL PARTS
Blower Housing Flame Roll-Out Switch
Blower Motor Gas Orifice
Blower Wheel Heat Exchanger
Burner High Limit Switch
Compressor Secondary Limit
Condenser Coil Ignitor/Flame Sensor
Condenser Fan Blade Induced Draft Motor
Condenser Fan Motor Pressure Switch
Contactor Pressure Switch Hose
Evaporator Coil Transformer
Fan Timer Board
Figure 18
Functional Parts List
GENERAL INFORMATION
1. Refer to the description in Figure 18 when ordering any
of the listed functional parts. Be sure to provide the unit
model, manufacturing, and serial numbers with the
order.
2. Although only functional parts are shown in Figure 18, all
sheet metal parts, doors, etc. may be ordered by de-
scription.
3. Parts are available from your Amana distributor.