Value Place Cleveland Ohio Submittal Data PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS WITH OUR DIGISMART® CONTROL BOARD & EMS PTAC SPECIFICATIONS AND ACCESSORIES CATALOG First-Year Warranty: Parts & Labor on entire unit Second through Fifth Year: Parts & Labor on certain sealed system components Second through Fifth Year: on certain functional parts only * Complete warranty details available at www.amana-ptac.com. p MC-DPTAC www.amana-ptac.
STANDARD FEATURES (QHUJ\ (IÀFLHQFLHV :LWK ((5V XS WR DQG &23V XS WR RXU XQLW·V KLJK HIÀFLHQFLHV PD\ TXDOLI\ \RX IRU PDQ\ RI WKH UHEDWHV offered by electrical power companies.
STANDARD FEATURES (CONT.) &RQGHQVDWH 'LVSHUVLRQ 6\VWHP Our condensate dispersion system removes condensate from indoor cooling operation by throwing ZDWHU GLUHFWO\ RQ WR WKH RXWGRRU FRLO IRU UDSLG HYDSRUDWLRQ DQG LQFUHDVHG FRROLQJ HIÀFLHQFLHV 7KH VOLQJHU ULQJ RQ WKH QHZ enhanced fan draws water up and into the fan blades. This water is then atomized and evaporated into the atmosphere through the condenser.
brings together our best PTAC ever with our best Energy Management Software and now integration with 3URSHUW\ 0DQDJHPHQW DQG )URQW 'HVN 0DQDJHPHQW 6RIWZDUH 5HGXFH 37$& HQHUJ\ FRQVXPSWLRQ E\ 25 025( WKURXJK the power of the in-unit Energy Management System, programmable temperature set-back and limits combined.
ENTERPRISE — MULTIPLE WIRELESS CONTROLLERS CENTRAL MONITORING AND CONTROL OF MULTIPLE PROPERTIES ! 'DWD :DUHKRXVLQJ > Savings Analysis > Email Reporting > Virtual Metering > Load Shedding WEB-BASED, REAL-TIME MONITORING AMANA® BRAND DIGISMART™ CONTROLLER: All of the PTACs in the building can be managed through a single interface on a PC.
NOMENCLATURE #* & $%& ' ( ) &( * + , $# $$ $% $& $' ( # & $$! & $& 9 #$& , ' $#' ( # & ( +"% +" $$! & ( # & $ ! $&&$' $# &$( )$# 7 $ '(8 =><<< 5 B< 0 +' $! & =A =@<<< 5 B< 0 / &$# $# #' ( +"% + ( ( > ==A 2 B< 02 =
PRODUCT SPECIFICATIONS: PTC MODELS — COOLING/ELECTRIC HEAT (CONT.) 230/208 VOLTS 8 units 125 units Dʽ ¹, ϼ, Ͼ, Ͽ Voltage ¹, ³ Capacity (BTU/h) Amps Ϸ϶ tĂƩƐ Ϸ϶ EER PTC 073G***XXX 230 / 208 7,700 / 7,700 3.5 / 3.5 PTC 093G***XXX 230 / 208 9,000 / 9,000 4.1 / 4.1 PTC 123G***XXX 230 / 208 11,700 / 11,500 5.6 / 5.6 PTC 153G***XXX 230 / 208 15,000 / 14,700 7.0 / 7.0 670/660 11.5/11.7 805/785 11.2/11.5 1135/1105 10.3/10.4 1500/1470 10.0/10.0 hÄ®ã ó®ã«Êçã ½ãÙ® ,ãÙ 4.2 4.9 6.8 8.
PRODUCT SPECIFICATIONS: PTH MODELS — COOLING/HEAT PUMP/ELECTRIC HEAT 230208 VOLTS Wd, Ϭϳϯ ΎΎ yyy Dʽ ¹, ϼ, Ͼ, Ͽ Voltage ¹, ³ Capacity (BTU/h) Wd, Ϭϵϯ ΎΎ yyy Wd, ϭϮϯ ΎΎ yyy Wd, ϭϱϯ ΎΎ yyy 230 / 208 230 / 208 230 / 208 230 / 208 7,600 / 7,500 9,000 / 8,900 11,500 / 11,100 14,000 / 13,900 Amps ¹² 3.5 / 3.5 4.1 / 4.1 5.6 / 5.6 7.0 / 7.0 tĂƩƐ ¹² 650 / 620 770 / 765 1095 / 1065 1460 / 1465 EER 11.3 / 11.4 11.1 / 11.1 10.2 / 10.1 9.6 / 9.5 hÄ®ã ó®ã«Êçã ½ãÙ® ,ãÙ Min.
PRODUCT SPECIFICATIONS: PTC / PTH MODELS — ELECTRIC HEAT PERFORMANCE 3ULPDU\ +HDWLQJ IRU 37& 0RGHOV $X[LOLDU\ +HDWLQJ IRU 37+ 0RGHOV 6HH EHORZ IRU 3RZHU &RUG &RQÀJXUDWLRQ) ½ãÙ® ,ã ;»tͿ EÊ͘ Ê¥ ^ã¦Ý 230/208V 2.5 230/208V 230/208V sʽ㦠133 units EÊîĽ ,ã®Ä¦ ; dhͬ«Ϳ dÊã½ tããÝϲ dÊã½ ÃÖÝ D®Ä͘ ®Ùç®ã ÃÖ®ãùϸ MOP4 ;ÃÖÝͿ WÊóÙ ÊÙ Λ ϮϯϬs Λ ϮϬϴs Λ Ϯϲϱs 1 8,500 6,800 -- 2,570 / 2,115 11.2 / 10.1 14.0 15 ϲͲϭϱ W 3.5 1 12,000 9,900 -- 3,570 / 2,935 15.5 / 14.
ACCESSORIES CUSTOM COLOR SLEEVES We offer over 150 different custom colors to choose from for your wall sleeves. In addition, we can custom paint the exterior a different color from the interior to meet your needs.
ACCESSORIES (CONT.) POWER DISCONNECT SWITCH The PSHW**A power disconnect switch can be used for 265-volt or 230/208-volt SK\VLFDO GLVFRQQHFW ZKHUH UHTXLUHG E\ ORFDO FRGHV 7KH VZLWFK LV UDWHG DW amp capacity. The switch is for use with and Amana® brand standard sub-bases or PTPWHWK4 Hard Wire Kit. FUSE HOLDER KIT Cartridge-style fuses can be installed in the fuse holder for use in the sub-base or chassis. Available in 15, 20 and 30 amp (included on 265-volt unit).
ACCESSORIES (CONT.) SECURITY KEY LOCKS ,Q FRQMXQFWLRQ ZLWK WKH WDPSHU UHVLVWDQW IURQW WKH LQVWDOODWLRQ RI $PDQD EUDQG security key locks prevents tampering of the controls used to set temperature, heating and cooling functions. UL approved for institutional use only. POWER DOOR KIT Vent door will automatically open when unit fan is on. THERMOSTATS The following thermostats offer remote control. Any thermostat other than those listed must be submitted to Goodman Company, L.P., for approval prior to use.
ACCESSORIES (CONT.) REMOTE TEMPERATURE SENSOR Unit can be wired to sense room temperature away from the PTAC to have accurate readings.
UNIT WITH ACCESSORY WALL SLEEVE AND SUB-BASE ACCESSORY TOP VIEW 42" 40" 6 - 1 / 8" 24 - 5 / 16" 1" 9 - 9 / 16" Location of external drain holes on bottom flange of Wall Sleeve Air Flow Air Flow Air Flow Control Door Air Discharge Grille 3 1" 3" Clearance to side walls " FRONT VIEW 58” LCDI CORD SET — 230V/208V UNIT* 42" LEFT R I GHT 16-1/16" 2-5/8" RIGHT VIEW AIR DISCHARGE GRILLE IS REVERSIBLE TO PROVIDE EITHER 15° OR 40° DISCHARGE ANGLE 7/8" STAMPED GRIL 3-1/4" MIN 21-1/2" 2" MAX 1-3/
FRAMING FOR ACCESSORY WALL SLEEVE (WS9XX) Alternative Fastening Method (Field Supplied) Wood Screw Toggle Bolt Expansion Anchor Bolt Mounting Holes (Drilled by Installer) Plastic Anchor Screws tĂůů ^ůĞĞǀĞ ŵƵƐƚ ĞdžƚĞŶĚ Ă ŵŝŶŝŵƵŵ ŽĨ Ь͟ ďĞLJŽŶĚ ŽƵƚƐŝĚĞ ǁĂůů ƚŽ ĂůůŽǁ ĨŽƌ ƉƌŽƉĞƌ ĐĂƵůŬŝŶŐ͘ JACK STUDS HEADER - 4" x 4" OR DOUBLE 2"x 4" ON EDGE MAIN STUD 16 1/4" MIN 42 1/4 " ADJUST FRAMING TO SECURE THIS DIMENSION JACK STUD CRIPPLE FINISHED FLOOR SUB-FLOOR tĂůů ƐůĞĞǀĞ ŽƉĞŶŝŶŐ ŚĞŝŐŚƚ ƐŚŽƵůĚ ďĞ ƐƋƵĂƌĞĚ ǁ
PACKAGED TERMINAL AIR CONDITIONERS AND HEAT PUMPS WITH CONTROL BOARD %XWWRQ &RQWURO 3DG One-Touch Activation Total Fan Control (DV\ WR 5HDG 'LVSOD\ First-Year Warranty: Parts & Labor on entire unit Second through Fifth Year: Parts & Labor on certain sealed system components Second through Fifth Year: on certain functional parts only p * Complete warranty details available at www.amana-ptac.com.
PTAC WALL SLEEVE INSTALLATION INSTRUCTIONS The wall sleeve must be installed before the air conditioner or heat pump chassis can be set in place. Read the instructions thoroughly before proceeding. When 230/208 volt units are to be installed, the power supply may be either cord connected or permanent wiring. Permanent wiring may be done through the hard wire junction box, or the accessory subbase. When 265 volt units are to be installed, the power supply must be permanent wiring.
KIT ACCESSORIES DRAIN KIT An indoor/outdoor drain kit is available as an accessory item. When a drain kit is to be installed, do so before installing the wall sleeve in the wall. See the drain kit for actual installation instructions. 4 10 2 1 / Mi 75 m 4" nim m um SUBBASE, LEVELING LEGS, MAIN DUCT, AND HYDRONIC HEAT KITS 16 1/4" 415 mm Minimum Installation of these kits requires drilling of mounting holes on both sides of the wall sleeve.
PRE-INSTALLATION CONSIDERATIONS Before proceeding with the sleeve installation, ensure the following guidelines for locating the wall opening and sleeve are met: • • • • • • • • The wall opening must be the correct size. See Figure 1 for wall sleeve dimensions and Figure 2 for minimum wall opening size. The wall sleeve will need to be installed with minimum clearances to the floor and adjacent walls. Minimum projections of the sleeve into and out of the room will also have to be met.
Figure 9 - Panel Removal WALL SLEEVE INSTALLATION After the wall opening is checked and approved for location, size, and clearances, complete the following to install the wall sleeve. 1. Remove the outside enclosure panel from the wall sleeve. Alternative Fastening Method (Field Supplied) 2. Slide the wall sleeve into the wall opening. Do not distort the cabinet shape to fit the wall opening; the unit chassis must fit snugly and uniformly into the wall sleeve.
PTAC Standard Louvered and Architectural Outdoor Grilles Installation Instructions Standard Louvered Grille NOTE: A baffle kit must not be used with a standard louvered grille on any PTAC installation. Before installing the grille, remove the cardboard stiffener and rear enclosure panel from the wall sleeve. These items can be removed from inside of the building. The sleeve stiffener must be taken out before the rear sleeve enclosure panel can be removed from the sleeve.
Architectural Louvered Grille NOTE: Some PTACs may include factory-installed baffles on the outdoor coil. Remove these baffles before installing the architectural grille. B 1. Remove the cardboard sleeve stiffener and the rear enclosure of the sleeve as described on page 1. 2. Install the four threaded studs (B, Figure 4) into the threaded openings on the inside face of the grille. 3. Manipulate the grille out through the rear sleeve opening using the plastic handle provided.
KEY LOCK INSTALLATION INSTRUCTIONS The installation and servicing of the equipment should be done by qualified experienced technicians. The Key Lock kit prevents tampering of the controls used to set temperatures and heating or cooling functions. CAUTION PERSONAL RISK HAZARD Underwriter’s Laboratories Inc. listed. For institutional use only where supervisory monitoring is available. Any other use may increase the risk of personal injury or property damage.
RAISING THE BAR IN PTAC CONTROLS Designed exclusively for Amana PTAC units, DigiSmart technology has dramatically raised the bar in PTAC controls. Your guests will appreciate its large, easy-to-read LED readout that allows them to check the temperature with a quick glance and, if desired, to change the setting to a specific temperature by pressing a button.
PTAC WIRELESS KITS (DT01A, DS01E, DD01E) INSTALLATION INSTRUCTIONS AIR CONDITIONING SENSOR DD01E A Heating & Air Conditioning ® DS01E DT01A The following installation instructions are for a typical installation. Please contact your PTAC salesperson for additional assistance and explanation prior to ordering materials or cutting openings. ATTENTION INSTALLING PERSONNEL As a professional installer you have an obligation to know the product better than the customer.
BEFORE BEGINNING INSTALLATION, PLEASE READ IMPORTANT NOTES BELOW: • If devices are to be powered, field installed wiring will need to be run from thermostat location to unit location and from door sensor location to PTAC location and from wired magnet to sensor location. • If wireless platform DP01, DP01E or DL01E are being utilized, then room numbers MUST BE CONFIGURED in the control board prior to binding wireless devices. • Front Mounting Screw accessed through louvers.
Mounting Sensor/Door Magnet Installation for DD01E Kit Thermostat Installation for DS01E Kit NOTE: A DT01* must be installed on the digital PTAC unit for the DS01* to be operable. Skip these steps if not installing. DDO1E must be mounted on the top door frame as close to the door as possible in the horizontal position. 1.
Door Magnet Installation WIRED MAGNET AND POWERED DOOR SENSOR OPTION NOTE: Magnet buckets are shipped from the factory with the magnets in position A. The position may change based on the door and door frame alignment on page 5. In cases where there is no top door frame, the sensor will need to be mounted on the wall next to the door. In these cases a wired magnet (a field supplied single pole single throw wired magnet) can be recessed or surface mounted and wired to the door sensor.
DOOR TRIM Security Screw location (located on each side of sensor) MAGNET MUST BE 15/16” FROM THE SENSOR MOUNTING PLATE MAGNET HOLDER MAY EXTEND ABOVE THE DOOR (OR THE DD01E MAY EXTEND BELOW THE DOOR FRAME) TO ENSURE THE MAGNET IS NO MORE THAN 1/8” FROM THE BOTTOM CENTER OF THE SENSOR 1/8” max. MAGNET THE SPACE FROM THE TOP OF THE MAGNET HOLDER AND THE BOTTOM OF THE DD01E CANNOT BE MORE THAN 1/8”.
CONSTRUCTION STYLE 1 CONSTRUCTION STYLE 2 Place magnet in Position A in instances when the door and frame align. Place magnet in Position B in instances when the door extends into the room beyond the door frame. POSITION A POSITION B CONSTRUCTION STYLE 3 CONSTRUCTION STYLE 4 Place magnet in Position C in instances when the door extends into the room beyond the door frame. Place magnet in Position A in instances when the door frame extends into the room beyond the door.
DD01E THE ALIGNMENT GUIDE IS AT 15/16” FROM BACK PLATE. AIR CONDITIONING SENSOR ALIGNMENT GUIDES ON BOTTOM OF DD01E SENSOR MOUNTING PLATE CENTER OF MAGNET (IN HOLDER) MUST BE 15/16” FROM THE SENSOR MOUNTING PLATE IMPORTANT NOTE: When properly installed, the center line mark on the bottom of the DD01E will line up with the center of the line of the magnet holder containing the magnet. Choose magnet position A, B, or C to align the magnet 15/16” from the back of the DD01E.
DPO1A, DP01E or DL01E Entering Room Number (Skip if not using DP01* Front Desk Platform) 1. The PTAC control can be set for a 4-digit room number. To select the first two digits (floor), press the HEAT key until appears, then press the up down arrows to select the first two digits. key until 2. To select the last two digits of the room number, press the HEAT and down appears, then press the up arrows to select the last 2 digits of the room number.
Binding of RF Devices 3. Press and then immediately release the white tactile button on the back of the DD01* motion sensor. or should now be displayed on the PTAC LED display. or does not show on the display in 1-2 secIf onds, then press and release the white button a second time. NOTE: If both a DD01* and a DS01* are being bound, then the display will show . Skip if there is no motion sensor.
CONFIGURATION SETTINGS CHART Configuration Code Description Option Code Description C1 Interface 0* Chassis Membrane* rE Wireless Remote L5 Wired Thermostat bP Button present bA* 7-Button, reverts to Cyclic A Always run fan (even in Off) bC 7-Button, reverts to Continuous C Cooler Only H* Heat Pump* 0 Service No Operation "Eo" C2 C3 Fan Operation Reverse Cycle Operation C4 Room I.D. Digit 1 & 2 00* - 99 00* - 99 C5 Room I.D.
Setback Temps - DD01E The DD01* and the DigiSmart™ control can be programmed for 3 different times to activate temperature setbacks. The current factory default temperature setbacks in v2.5 * software release are: 2º from set point in 30 minutes, 3º in one (1) hour, and 6º in three (3) hours. For each time, you can select a setback temperature. The amount of setback is the amount of degrees the control will operate from guest’s setting in degrees F.
9. Press HEAT key to scroll to third unoccupied setback time. Press either the up or down arrow to the desired third unoccupied setback time. 10. To exit configuration mode: Press the OFF key. NOTE: Configuration feature mode will also automatically exit if no keys are pressed for a period of two (2) minutes. The changes made in configuration mode are now in effect. NOTE: Additional codes are present and may be accessed within this menu. Contact the manufacturer for additional information.
Suggested Wireless Thermostat Locations in Typical Room Layouts Select thermostat mounting location about five feet above the floor, on an inside wall, out of direct sunlight, away from sources of radiant heat (lamps, fireplaces, heating and air conditioning equipment, etc.), away from windows or door to the outside, and avoid areas with poor air circulation. Ensure location is out of the path of foot traffic where a person might accidentally bump into the thermostats and damage the device.
THIS PAGE LEFT BLANK INTENTIONALLY 14
THIS PAGE LEFT BLANK INTENTIONALLY 15
is a registered trademark of Maytag Corporation or its related companies and is used under license to Goodman Company, L.P., Houston, TX. All rights reserved. ® Goodman Company, L.P. 5151 San Felipe, Suite 500 • Houston, TX 77056 www.amana-ptac.com • © 2009 Goodman Company, L.P.
THROUGH-THE-WALL DESIGN FOR FLUSH-MOUNT APPLICATIONS COOLING-ONLY OR ELECTRIC HEAT OR HEAT PUMP MODELS Specifications for: Cooling Models: PBC092E00BB PBC122E00BB PBC093E00BB PBC123E00BB Electric Heat Models: PBE093E35BB PBE123E35BB Heat Pump Models: PBH092E12BB PBH093E35BB PBH113E35BB OFFERING TOTAL COMFORT WITH EASY-TO-USE CONTROLS! t ELECTRONIC TOUCH PAD WITH REMOTE CONTROL t HIGH ENERGY EFFICIENCY WITH MODELS UP TO 9.8 EER saving you money when compared to lower EER models.
Cooling Only Models Amana® brand Model PBC092E00BB Electric Heat Models PBC122E00BB PBC093E00BB PBC123E00BB PBE093E35BB PBE123E35BB Heat Pump Models PBH092E12BB PBH093E35BB PBH113E35BB General Features: Voltage 115 115 230 / 208 230 / 208 230 / 208 230 / 208 115 230 / 208 230 / 208 Approx. chassis weight 75 lbs 77 lbs 75 lbs 77 lbs 77 lbs 79 lbs 79 lbs 79 lbs 81 lbs Approx.
® PBWS01A Wall Sleeve Installation Instructions General Information The wall sleeve must be installed before the air conditioner chassis can be set in place. Read the instructions thoroughly before proceeding. Table of Contents General Information ................................................................. 1 Preinstallation Considerations ................................................ 2 Wall Sleeve Installation ........................................................... 3 Condensate Drain Kit ..
Preinstallation Considerations Before proceeding with the sleeve installation, ensure the following guidelines for locating the wall opening and sleeve are met: • The wall opening must be the correct size. See Figure 15 3/4" 401 mm • • 26" 661 mm 16 3/4" 426 mm Figure 1 Wall Sleeve Dimensions 1 for wall sleeve dimensions and Figure 3 for minimum wall opening size. The wall sleeve must be installed with a 5” minimum clearance to the floor and 1 1/2” to adjacent walls.
Waterproof barrier should remain in place until the unit is installed. An accessory metal front panel, PBWMFC, is also available, but must be purchased separately. Wall Sleeve Installation After the wall opening is checked and approved for strength, location, size, and clearances, install the wall sleeve as follows: • Attach the sleeve using four #12x2” wood screws (for 1. Remove the outside enclosure panel from the wall sleeve. 2. Slide the wall sleeve into the wall opening.
©2002 - 2006 Goodman Company, L.P.