Specifications

B-6
42"
(1066.8mm)
13-3/4"
(349.3mm)
16-1/16"
(408 mm)
ACCESSORIES
Wall Sleeve (42” wide x 16-1/16 high x 13-3/4” deep)
Standard insulated wall sleeve fits all Amana Packaged
Terminal Units. Shipped separately to allow installation
during construction.
Outdoor Grilles
Available in stamped aluminum and an attractive ex-
truded aluminum architectural grille for application with
WS900B wall sleeve. The architectural grille is avail-
able in anodized natural, 3 stock colors and custom
colors to blend with the building exterior. CB=Clear,
DB=Dark Bronze, ZB=Driftwood, WB=White,
SB=Special (Custom) Color
Remote Temperature Sensor
Allows inexpensive, low voltage temperature sensing on
internal wall for more accurate temperature control.
Hard Wire Kit (not shown)
Used to permanently wire to chassis when standard sub-
base and power cord are not utilized.
Subbase Kit
The fully skirted subbase conceals wiring while provid-
ing strong support, if needed. Plug-in receptacle and
field wiring access speeds installation. Electrical ac-
cessories such as fuse holders, circuit breakers and dis-
connect switches meet N.E.C. requirements.
Fuse Holder Kit (not shown)
Cartridge style fuses can be installed in fuse holder for
use in subbase or chassis. Available in 15, 20 and 30
amp. (Included on 265v unit).
Circuit Breaker Kit (230/208v only)
The circuit breaker kit, available in 15, 20, 25 or 30 amp,
can be used with Amana's subbases. It gives overcur-
rent protection and its location allows turning unit on or
off without tools.
Power Disconnect Switch (not shown)
The PSHW**A power disconnect switch can be used
for 265 or 230/208 volt physical disconnect where re-
quired by local codes. The switch is rated at 30 amp
capacity. The switch is for use with Amana's standard
subbases or PTPWHWK4 Hard Wire Kit.
Condensate Drain Kit
Attaches to the wall sleeve base pan for controlled in-
ternal or external disposal of condensate
.
FHK315C 230/208V 15A
FHK320C 230/208V 20A
FHK330C 230/208V 30A
PSHW03A 230/208V
PSHW04A 265V
WS900B Wall Sleeve
PTPWHWK4 Hard Wire Kit
Skirting
Skirting
Leveling Legs
Optional
Fuse Holder
Location
Optional
Power Switch and Circuit Breaker
Location
Power Receptacle
Subbase Box Assembly
Gasket
Cover
Plate
1/2" OD
Drain Fitting
(12.7mm)
CBK3**C Circuit Breaker Kit
RTS01
Remote
Temperature Sensor
®
60
70
80
90
60
70
80
90
®
AIR
CONDIT IONING
Thermostats
The following thermostats offer remote control. Any thermostat other
than those listed must be submitted to Amana for approval prior to use.
NOTE: DO NOT CONNECT THE X1 TERMINAL.
Standard Outdoor Grille
SGK01B Single Pack
SGK10B Ten Pack
Architectural Grille
AGK01*B Single Pack
PTSB320C 230/208V 15/20A
PTSB330C 230/208V 30A
PTSB420C 265V 15/20A
PTSB430C 265V 25A
SGK
AGK
Heat Stages Cool Stages Programmable Shape
D9807605 2
1 Yes Rectangle
D9945801 2
1 No Rectangle
D6853511 1
1 No Rectangle
C5200609 1
1 No Round
20189101* 2
1
No (Auto Changeover)
Rectangle
* Note: Thermostats listed above are manual changeover except for 20189101
DK9001
Condensate