PTAC Brochure/Spec Sheet

7
Specifications and Accessories Catalog
Product Specifications: PTC Models — Cooling/Electric Heat
230/208 Volts
Model
,
,
PTC
073G***XXX
PTC
093G***XXX
PTC
123G***XXX
PTC
153G***XXX
PTC
173G***XXX
Voltage  230 / 208 230 / 208 230 / 208 230 / 208 230 / 208
Capacity (BTU/h) 7,000 / 7,000 9,200 / 9,000 11,900 / 11,700 14,800 / 14,500 16,700 / 16,400
Amps
 3.1 / 3.1 4.1 / 4.1 5.0 / 5.0 7.0 / 7.0 8.4
Watts
 580 / 560 790 / 765 1045 / 1035 1,500 / 1,470 1,725 / 1,705
EER 12.0 / 12.5 11.6 / 11.7 11.0 / 11.0 10.0 / 10.0 9.7 / 9.7
Unit without Electric Heater
Min. Circuit Amps
,
,
 3.7 5.0 6.1 8.5 10.2
CFM (Cool/Wet Coil)
High 290 290 290 340 340
Low 264 264 264 314 314
CFM (Dry Coil)
High 310 310 310 360 360
Low 282 282 282 332 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4 4.8
Net Weight (lbs.) 98 102 102 113 113
Ship Weight (lbs.) 113 117 119 130 130
265/277 Volts
Model
,
,
PTC074G
***XXX
PTC094G
***XXX
PTC124G
***XXX
PTC154G
***XXX
Voltage 
,
265 265 265 265
Capacity (BTU/h) 7,000 9,100 12,200 14,800
Amps
 3.0 3.6 4.8 6.0
Watts
 658 796 1,154 1,480
EER 11.9 11.3 10.4 10.0
Unit without Electric Heater
Min. Circuit Amps
,
,
 3.6 4.4 5.9 7.4
CFM (Cool/Wet Coil)
High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)
High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidification (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 98 102 102 113
Ship Weight (lbs.) 113 117 119 130
* Actual vent CFM performance will vary due to application and installation conditions.
N
All 265-volt models must use an Amana® brand sub-base (PTSB4**E) or an Amana® brand hard-wire kit PTPWHWK4 and
disconnect switch PSHW04A.
Minimum Circuit Ampacity (MCA) ratings conform to the National Electric Code; however, local codes should apply.
Minimum voltage on 230/208-volt models is 197 volts; maximum is 253 volts. Minimum voltage on 265-volt models is 239 volts;
maximum is 292 volts.
Overcurrent protection for all units without electric heaters is 15 amps. Overcurrent protection on 265-volt models must be
cartridge-style time-delay fuses (included and factory-installed on all Amana® brand 265-volt chassis). See heater performance
Heating capacity and eiciency based on unit operation without condensate pump.
Specify two-digit heater kW size to complete model number.
R-410A refrigerant used in all systems.
All units meet or exceed ASHRAE 90.1 standards.
All units less than 250 volts have a Leak Current Detector Interrupter (LCDI) power cord and meet UL 484 standards.
 Refer to electric heat performance data for total MCA and recommended overcurrent protection. Amps and Watts notation
refers to compressor only.