R-410A PTAC/PTHP Spec Sheet
SS-DPTAC www.amana-ptac.com PB
8 www.amana-ptac.com SS-DPTAC
P
roduct
S
PecificationS
P
roduct
S
PecificationS
Amana® is a trademark of Maytag Corporaon or its related companies and used under license to Goodman Company, L.P. All rights reserved. Our connuing
commitment to quality products may mean a change in specicaons without noce. © 2013 • Goodman Company, L.P. • Houston, Texas • Printed in the USA.
NewinstallaonstypicallyrequireaminimumofWS900Dwallsleeveandanoutdoorgrille.
WAll sleeves (Ws900e)
The wall sleeve must be industry-accepted dimensions:
14⅛”depthx42”widthx16¹/
₁₆
”heightandconstructedof
G90HDGgalvanizedsteelwithabakedcorrosion-inhibing
urethane primer and baked-polyester topcoat enamel.
Sleeve must be insulated and shipped with a weather
resistantrearclosurepanelinstalled.
ouTdoor Grilles
Outdoor grille must be architecturally extruded, louvered
aluminum (AGK01*B), one-piece polymer-blend injecon
molded louver (PGK01*B) or standard stamped aluminum
(SGK**B). All other grilles must be submied to the PTAC
manufacturer for feasibility, airow characteriscs and
compliancewithULregulaons,wherenecessary.
Theoponalaccessorieslistedbelowperformspecicfunconsrequiredinsomeinstallaons.
CondensATe drAin KiT (dK900d)
Aaches to the boom of the wall sleeve for direconal-
controlled internal or external disposal of condensate,
defrostorrainwater.
subbAse KiT (PTsb***e)
NecessaryforULlisngrequirementsfor265Vunits (Hard
WireKit maybe substuted forSubbase kit). Oponal for
230/208Vunits.Mustbepre-wiredtofacilitateeld-electrical
connecons and include an NEMA 6 or 7 conguraon
electrical receptacle. It must have two leveling screws for
sleevesupportandaccurateunitlevelingduringinstallaon.
Locaons for eld installaon of physical disconnect
switches, cartridge-style fuse holders and circuit breakers
must be provided. Side-skirts must be provided with sub-
bases.(PTSB000E Non-Electrical Subbase available.)
PoWer venT & dAmPer
Mustbeprovidedtomaximizevenlaonairintaketoupto
approximately95CFM.Powerventmustbeoanddamper
doorclosedwhenunitfanisde-energized.
fuse Holder (inCluded in 265v CHAssis)
Mustbeinstalledeitherintheunitorthesubbaseandmust
matchtheelectricalrequirementsofthechassis.
seCuriTy Key loCKs (Kl03e)
Mustbeinstalledtopreventtamperingoftheunitcontrols.
Unitroomcabinetmustalsobesecuredtothechassiswith
eldsuppliedscrews.UL-approvedforinstuonaluseonly.
disConneCT sWiTCH
Power disconnect switch must be installed in subbase for
useasaphysicaldisconnect,whererequiredbylocalcodes.
duCT KiTs (mdK01e, edK02b, TdK02b, PTdK01e, ddK01e)
Threekitsmustbesuppliedtoprovideducted,condioned
airintoasecondroom:amainductkit,anextensionductkit
andaterminalductkit.
HydroniC HeAT KiT
Isrequiredforheangfunconsinsteadofelectricresistance
heaters.Unitmustretaincompleteserviceaccesswiththe
kitinstalled.Properwaterorsteamvalvesmustbeused.
CondensATe removAl PumP (HeAT PumPs only)
Must be installed to assist in removing the condensate
developedbytheheatpumpoperaonandtransferittothe
indoor coil to dissipateinto the room,adding humidity to
theroom.
CirCuiT breAKer KiT
Must be installed in subbase to provide overcurrent
protecon for proper 230/208V amperage. Can also be
usedasaphysicaldisconnectwherelocalcodespermitfor
230/208voltage.
HArd Wire KiT
Must be used to permanently wire chassis for hard wire
purposes.(For265Vunits,HardWireKitmaybesubstuted
withSubbaseKit.)
THermosTATs
A manufacturer-approved manual, auto changeover or
programmable tradionally wired thermostat must be
installedtoprovidefullremoteoperaonofthechassis.A
Remote Escutcheon Kit must be used to indicate remote
operaon.