Product specifications

8 www.amana-ptac.com CT-DPTAC
Product SPeciFicationS: Pth modelS — cooling/heat PumP/electric heat
230208 Volts
model ¹
, 6, 8, 9
PTH
073E**AXXX
PTH
093E**AXXX
PTH
123E**AXXX
PTH
153E**AXXX
Voltage ¹, ³ 230 / 208 230 / 208 230 / 208 230 / 208
Capacity (BTU/h) 7,600 / 7,500 9,000 / 8,900 11,500 / 11,100 14,000 / 13,900
Amps
10
3.5 / 3.5 4.1 / 4.1 5.6 / 5.6 7.0 / 7.0
Watts
10
650 / 620 770 / 765 1095 / 1065 1460 / 1465
EER 11.7 / 12.1 11.7 / 11.6 10.5 / 10.4 9.6 / 9.5
UNit WitHoUt electric Heater
Min. Circuit Amps ²
, 4, 10
4.2 5.0 6.8 8.5
CFM (Cool/Wet Coil)
High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)
High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidi cation (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 108 112 115 126
Ship Weight (lbs.) 123 127 132 143
265,277 Volts
model ¹
, 6, 8, 9
PTH
074E**AXXX
PTH
094E**AXXX
PTH
124E**AXXX
PTH
154E**AXXX
Voltage ¹, ³ 265 265 265 265
Capacity (BTU/h) 7,500 9,000 11,500 14,000
Amps
10
3.0 3.6 4.8 6.0
Watts
10
635 780 1115 1430
EER 11.8 11.5 10.3 9.8
UNit WitHoUt electric Heater
Min. Circuit Amps ²
, 4, 10
3.6 4.4 5.9 7.3
CFM (Cool/Wet Coil)
High 290 290 290 340
Low 264 264 264 314
CFM (Dry Coil)
High 310 310 310 360
Low 282 282 282 332
Ventilated Air, CFM (Fan Only)* 65* 65* 65* 65*
Dehumidi cation (Pints/Hr.) 1.7 2.2 3.6 4.4
Net Weight (lbs.) 108 112 115 125
Ship Weight (lbs.) 123 127 132 142
* Approximately 95 CFM with optional power vent kit. Actual vent CFM performance will vary due to application and installation conditions.
See Notes on previous page