Owner`s manual

5
Installation
Earthing Instructions
Warning
This equipment must be earthed.
RC517*/RC519* requires a dedicated 230 volt, 16 amp
50 hertz circuit. Oven main lead wires are colored as
follows:
Earth—Green and Yellow
Neutral—Blue
Live—Brown
If oven main lead wire colors do not correspond with
terminal plug markings or colors, match plug terminals
according to following markings:
E—Earth
N—Neutral
L—Live
Unpacking Equipment
Inspect equipment for damage such as dents in
door or dents inside oven cavity.
Report any dents or breakage to source of
purchase immediately. Do not attempt to use
oven if damaged.
Remove all materials from oven interior.
If oven has been stored in extremely cold area,
wait a few hours before connecting power.
Equipment Placement
Do not install equipment next to or above source
of heat, such as pizza oven or deep fat fryer. This
could cause microwave oven to operate
improperly and could shorten life of electrical
parts.
Allow air flow around oven. Air flows around
electric components. At least 1½ inch of
clearance is required at top and sides of
equipment to provide proper ventilation. With
restricted air flow oven may not operate properly
and life of electrical parts is reduced.
Allow 6.5 centimeters (2
9
/16 inches) between air
discharge on back of equipment and back wall.
Do not block or obstruct oven filter. Allow access
for cleaning.
Radio Interference
Microwave operation may cause interference to radio,
television, or similar equipment. Reduce or eliminate
interference by doing the following:
Clean door and sealing surfaces of oven
according to instructions in
Care and Cleaning
section.
Place radio, television, etc. as far as possible
from oven.
Use a properly installed antenna on radio,
television, etc. to obtain stronger signal reception.