INSTALLATION AND OPERATION INSTRUCTIONS FOR WALL-MOUNT AND BUILT-IN UNITS WM-FM-50-BG -NOLOG SAFETY INFORMATION WARNING If the information in these instructions are not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS....................................................................................................................... 3 UNPACKING AND TESTING APPLIANCE ...........................
IMPORTANT INSTRUCTIONS 1. Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front of the heater; keep them away from sides and rear as well. 3. Always unplug heater when it’s not in use. 4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way. 5. Do not use the heater outdoors. 6.
UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a conveniently located 120 Volt grounded outlet. GROUNDING APPLIANCE This appliance is for use on 120 Volts. The cord has a plug as shown in (A). An adapter as shown in (C) is available for connecting three-blade grounding type plugs to two-slot receptacles.
WM-FM-50-BG-NOLOG Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in or Wall Mount Appliance 120V AC 60Hz 1500W Max 25W 19W 47 1/2” or 120.
REMOVING FRONT GLASS The fireplace have 2 screws that secure the front glass in place. Two people are required for the installation process. 1. The screws are located on the sides of the unit. Once located, unscrew the two or four screws. You can then lift the front glass from the 4 shoulder posts on the sides of the unit and remove the glass. Screw locations on uint Lift glass from shoulder posts 2. To replace the glass, lift onto the 4 shoulder posts.
INSTALLATION-WALL MOUNT 1. Select a location that is not prone to moisture and is located at least 0.91 m or 3 feet away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc. 2. Referring to Fig. 1 below select a suitable position in which to mount the heater horizontally – use a spirit level to achieve Fig. 2 this. 3. Check the wall to ensure there is no wiring, pipe wires etc in the area to be drilled.
INSTALLATION- BUILT-IN 1. Select a location that is not prone to moisture and is located at least 0.91m or 3 feet away from combustible materials such as curtains or drapes, furniture, bedding, paper, etc. 2. Mark the desired location on the floor and store appliance in a safe, dry and dust free location. 3. Prepare a wall with a framed opening to accommodate the size of your unit. Leave at least 1/4” (6 mm) around the edge of the appliance.
HARD- WIRE INSTALLATION Turn off the appliance completely and let cool before servicing. Only a qualified service person should service and repair this electric appliance. If it is necessary to hard wire this appliance, a qualified electrician must remove the cord connection, and wire the appliance directly to the household wiring. This appliance must be electrically connected and grounded in accordance with local codes, if hard wired. In the absence of local codes, use the current CSA C22.
MEDIA OPTIONS The only media that comes with this version is ‘Clear decorative media’. Consumers may purchase optional decorative media if they choose. See dealer for more details. Clear DECORATIVE MEDIA INSTALLATION Removing the front glass Unplug the unit from wall and make sure controls are switched off. Unscrew two screws both hand side to take off the front glass. Installing the decorative media Pour the fire glass media into the tray.
OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. The main power ON/OFF switch in position O, the fireplace is OFF. 2. When main power ON/OFF switch is at position I, the fireplace is ready to use. 3. Press the Heat button repeatedly to set the heater to desired heat setting.
REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and main power switch located on the bottom left hand side is at position I. When operating the remote make sure you point the remote to the centre of the fireplace and make sure each time you press the button the buzzer inside the unit will bee ponce. It takes some time for the receiver to respond to the transmitter. Do not PRESS the buttons more than once within two seconds for correct operation.
INSTALLING WALL THERMOSTAT WALL THERMOSTAT WIRING DIAGRAMS NOTE: THE WALL THERMOSTAT WILL WOKING WHEN THE HEATER ON TEMP. SETTING. PLEASE REEFER TO THE MANUAL CONTROL AND THE REMOTE CONTROL. Wire the wall thermostat prior to installing the fireplace. WALL THERMOSTAT WIRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2. Remove cover plate located on the left side of appliance. 3.
REPLACEMENT PARTS NO PART NUMBER 1 DESCRIPTION QTY.
EXPLODED VIEW 15
TRUBLE SHOOTING PROBLEM POSSIBLE CAUSE Dim or no flame Flame LED’s are burnt out Ember bed is not glowing or dimming Appliance turns off and will not turn on Appliance will not come on when switch is flipped to ON SOLUTION Inspect the LED’s and replace them if necessary. Ember LED’s are burnt out Inspect the ember bed LED’s and replace them if necessary.
SERVICE HISTORY This heater must be serviced annually depending on usage.