OUTDOOR INSTALLATIONS
The BI-DEEP-XT series electric fireplaces are suitable for installation in outdoor areas protected from
direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a
rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed
appliance. See illustration below. All wiring connections to line power shall be in accordance with local
building code requirements. Inquires about local codes and regulations must be done prior to
installation.