INSTALLATION AND OPERATION INSTRUCTIONS FOR SYM-34 34-B 42-B SYM-42 SYM-50 50-B SYM-60 60-B SYM-74 74-B SYM-88 88-B SYM-100 100-B INSTALLER: LEAVE THIS MANUAL WITH THE APPLIANCE. CONSUMER: RETAIN THIS MANUAL FOR FUTURE REFERENCE.
TABLE OF CONTENTS Please read and carefully follow all of the instruction found in this manual. Please pay special attention to the safety instructions provided in this manual. The instructions included here will assure that you have many years of dependable and enjoyable service from your Amantii product. IMPORTANT INSTRUCTIONS .........................................................................................................................................3 UNPACKING AND TESTING APPLIANCE .........
IMPORTANT INSTRUCTIONS 1. Read all instructions before installing or using this heater. 2. Keep combustible materials, such as furniture, pillows, bedding, papers, clothes and curtains at least 3 feet from the front, sides and rear of the heater. 3. Always unplug heater when not in use. 4. Do not operate the fireplace if it has a damaged cord or plug, after it has malfunctioned, or if the unit has been dropped or damaged in any way. 5. Do not run the cord under carpeting.
appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.
Cautions Do’s Always install the heater in accordance with this guide. If in doubt obtain expert advice. Always make sure the electrical socket is accessible and located adjacent to, but not above the heater. Always disconnect the heater from the electrical supply before moving it, or carrying out cleaning, maintenance. Always make sure the heater is firmly secured to prevent it from being tipped over. Always use a fireguard when young children and infirm persons can come into contact with the heater.
UNPACKING AND TESTING APPLIANCE Carefully remove the appliance from the box. Prior to installing the appliance, test to make sure the appliance operates properly by plugging the power supply cord into a 120 Volt grounded outlet. Test all aspects of its operation (manual switches, remote and heater) to make sure all components are operating correctly. As with most electronic devices, your new electric fireplace has been designed to operate at temperatures between 5 ℃ (41℉ ℉) and 35 ℃ (95℉). ).
SYM-34-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 26W 19W 32 3/8” or 82.3 cm 15 5/8 ” or 39.
SYM-42-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 31W 19W 42 1/4” or 107.2 cm 15 5/8 ” or 39.
SYM-50-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 33W 19W 50 1/4” or 127.6 cm 15 5/8 ” or 39.
SYM-60-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 35W 19W 60 1/4” or 153 cm 15 5/8 ” or 39.
SYM-74-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 36W 19W 74 1/4” or 188.5 cm 15 5/8 ” or 39.
SYM-88-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU Built-in Appliance This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. 120V AC 60Hz 1200W Max 38W 19W 88 1/4” or 224.1 cm 15 5/8 ” or 39.
SYM-100-B Description Voltage Watts NO HEATER MOTOR HEATER Appliance Width Appliance Height Appliance Depth Gross Weight Plug Location Cord Length Rough Wall Opening Size BTU This appliance has been tested in accordance with the UL Standard 2021 for fixed and location dedicated electric room appliances in the United States and Canada. If you need assistance during installation, please contact your local dealer. Built-in Appliance 120V AC 60Hz 1200W Max 39W 19W 100 1/4” or 254.6 cm 15 5/8 ” or 39.
FOR BATHROOM USE If this unit is installed in a bathroom it must be protected by a GIF receptacle or circuit. If receptacle is used it must be readily accessible. To prevent electric shock, please be aware that this unit is an electrical appliance that is NOT watertight and must be installed as to prevent water from entering unit. This must be installed away from shows, tubs, etc. Never locate fireplace where it may fall into a bathtub or other water container.
OUTDOOR INSTALLATIONS The SYM-B series electric fireplaces are suitable for installation in outdoor areas protected from direct water impingement. In addition to maintaining the listed mantel and combustibles clearances, a rain protection overhang factor of 1/2 shall be constructed to the front and to each side of the installed appliance. See illustration below. All wiring connections to line power shall be in accordance with local building code requirements.
INSTALLATION-WALL WALL MOUNT NOTE: Due to the many different materials used to build walls, it is highly recommended that you consult your local builder before you install this appliance on a wall. 1. Select a location that is not prone to moisture and is located at least 0.91 m or 3 feet away from combustible materials rials such as curtains or drapes, furniture, bedding, paper, etc. 2. Using a spirit level to select a position in which to mount the heater horizontally. See Figure 1. 3.
INSTALLATION- BUILT-IN IN NOTE: Due to the many different materials used to build walls, it is highly recommended that you consult your local builder before you install this appliance on a wall. Preparation 1. Select a location that is not prone to moisture and is located at least 0.91m or 3 feet away from combustible materials such as curtains, drapes, furniture, bedding, paper, etc. 2. Mark the desired location on the floor and store the appliance in a safe, dry and dust free place. 3.
2. When the trim is removed, take off the front glass panel. 3. Unscrew the 2 screws located on each side and take off the inner side steel panels.
4. Put the trim back onto the appliance and fasten with screws.(NOTE: This step is to make sure that the fireplace fits the wall opening well and there is no gap between the trim and the wall after installation) 5. Put the fireplace into the wall opening and fix it to the wall by screwing 2 screws each side.
6. Remove the trim following STEP 1. Screw back the inner side steel panels. 7. Put back the front glass panel and screw back the trim after you finish the media decoration.
INSTALLATION SEMI-FLUSH FLUSH BUILT-IN BUILT WITHIN 2 X 4’S NOTE: Please purchase special trim for the semi-flush semi built-in in installation from dealer. See dealer for more details. The rough wall opening size of the fireplace: W(“) D(“) H(“) SYM-34-B 33 3/8 4 16 SYM-42-B 43 1/4 4 16 SYM-50-B 51 1/4 4 16 SYM-60-B 61 1/4 4 16 SYM-74-B 75 1/4 4 16 SYM-88-B 89 1/4 4 16 SYM-100-B 101 1/4 4 16 1. Unscrew 4 screws and take off the trim.
2. When the trim is removed, take off the front glass panel. 3. Unscrew the 2 screws located on each side and take off the inner side steel panels.
4. Put the trim back onto the appliance and fasten with screws.(NOTE: This step is to make sure that the fireplace fits the wall opening well and there is no gap between the trim and the wall after installation) 5. Put the fireplace into the wall opening and fix it to the wall by screwing 2 screws each side.
6. Remove the trim following STEP 1. Screw back the inner side steel panels. 7. Put back the front glass panel and screw back the trim after you finish the media decoration.
HARD- WIRE INSTALLATION Turn off the appliance completely and let cool before servicing. Only a qualified service person should service and repair this electric appliance. If it is necessary to hard-wire wire this appliance, a qualified electrician must remove the cord connection, and wire the appliance directly to the house hold wiring. This appliance must be electrically connected and grounded in accordance with local codes, if hard-wired. wired. In the absence of local codes, use the current CSA C22.
MEDIA OPTIONS The only media that comes with this appliance is ‘Clear decorative media’. Consumers may purchase optional decorative media if they choose. See dealer for more details. Clear DECORATIVE MEDIA INSTALLATION Unscrew 4 screws and take off the trim. (NOTE: Keep hold of the front glass as it may fall down automatically when the trim is removed.) Screws locations magnetic stones locations INSTALLING THE DECORATIVE MEDIA Pour the fire glass media into the tray.
OPERATION The fireplace can be operated either by the switches located on the left bottom of the fireplace unit or by supplied remote control. Plug the fireplace into a 15 Amp wall socket. MANUAL OPERATION 1. Press the Heat button repeatedly to set the heater to desired heat setting. The heater indicator LED will glow which shows the current heater settings.
REMOTE CONTROL OPERATION For remote to function make sure the heater is plugged in and the main power switch located on the bottom left hand side is at position I. Important: When operating the remote make sure you point the remote to the center of the fireplace each time you press the button. There will be a beep tone emitted. There can be a slight delay for the receiver to respond to the transmitter. Do not PRESS the buttons more than once within two seconds for correct operation.
INSTALLING WALL THERMOSTAT WALL THERMOSTAT WIRING DIAGRAMS NOTE: The wall thermostat will be functioning when the heater is on the TEMP. setting. Wire the wall thermostat prior to installing the fireplace. WALL THERMOSTAT WIRING(24 VAC) Install Wall Thermostat per instructions provided with kit and per the following information: 1. Turn off circuit breaker. 2. Remove cover plate located on the rear upper left side of the appliance. 3. Pull the wire out and cutt the inside thermostat.
REPLACEMENT PARTS PART NUMBER NO DESCRIPTION QT Y SYM-34-B SYM-42-B SYM-50-B SYM-60-B 1 10701358 10701359 10701346 10701347 FRONT GLASS 1 2 3200503 3201503 3202503 3203503 TRIM 1 3 10702224 10702225 10702210 10702211 EMBER BED GLASS 1 4 10702217 10702218 10702219 10702220 BACK GLASS 1 5 601141B 601141B 601141 601141 6 601142B 7 8 601136B 601137B 9 10 601137B 601136B 601137B 601137B 10101225 3200505 3201505 3155505 3156505 11 12 13 601032B 601097B 601092C
PART NUMBER NO DESCRIPTION QT Y SYM-74-B SYM-88-B SYM-100-B 1 10701348 10701363 10701364 FRONT GLASS 1 2 3204503 3205503 3206503 TRIM 1 3 10702212 10702226 10702227 EMBER BED GLASS 1 4 10702221 10702222 10702223 BACK GLASS 1 5 601141 601141 601141 6 601142 601142 601142 7 601136B 601136B 601136B 8 601137B 601137B 601137B 9 10 10101225 3157505 3205505 3206505 11 LED STRIP FOR FLAME LED STRIP FOR EMBER BED FLAME MOTOR 1 FLICKER ASSEMBLY 1 FIRE BOX 1 1
EXPLODED VIEW 32
TROUBLE SHOOTING PROBLEM POSSIBLE CAUSE SOLUTION Dim or no flame Flame LED’s are burnt out Inspect the LED’s and replace them if necessary Change a new flicker and back black cloth Inspect the ember bed LED’s and replace them if necessary Turn off the main switch, allow appliance to cool for 10 minutes, then turn it on Ember bed is not glowing or dimming Appliance turns off and will not turn on Appliance will not come on when switch is flipped to ON Back black cloth is falling off and roll the flic
SERVICE HISTORY This heater must be serviced annually depending on usage.
WARRANTY FOR PRODUCTS MANUFACTURED AFTER JANUARY 1st, 2016 Amantii Imports Corp. ("Amantii " ) warrants that your newly purchased Amantii electric fireplace is free from manufacturing and material defects for a period of two (2) years from the date of the first purchase, subject to the conditions and limitations contained below.