Specifications

Test Procedure
VISUAL INSPECTION STAGE
1. Physical checks
All screws for tightness, referring to the torque setting of the manufacturing tools
Capacitors for polarity where applicable
All wiring points for good contacts (soldering and crimping)
PRETESTING
PRE TESTING SETUP REQUIREMENT
a) Oscilloscope
b) Variac
c) Multimeter
d) Load [8ohm]
2. Set up device for test :
2.1. Fuse check
2 x DC fuses (3.15A), 20x5mm
1 x AC fuses (2A), 20x5mm
2.2. Connections
Connect unit to:
Variac (240Vac), power initially off
Signal generator (DVD1 left input, no signal)
Resistive load (8ohm on left amplifier output) with meters/oscilloscope
3. Power up :
Adjust voltage to 240VAC. Turn on variac power. Watch current meter for excess current
draw.
(P/F) Current shall not exceed <?>A (AC current)
3.1. Voltages
(P/F) Measure the following DC voltages with a multimeter referenced to ground
testpoint TP6 on the 07900 PCB.
Location Pass Range
Low Rail Filtered Pos U7 pin 1 7VDC to 10VDC
Low Rail Filtered Neg U8 pin 2 -7VDC to -10VDC
Regulated +5V TP1 4.7VDC to 5.3VDC
Regulated -5V TP3 -4.7VDC to –5.3VDC
High Rail Filtered Pos TP4 35VDC to 39VDC
High Rail Filtered Neg TP5 -35VDC to -39VDC
4. Programming :
Connect the programming pod to connector CN11 and follow the programming procedure
document.
(P/F) The programming must complete successfully.
5. Functional Checks :
5.1. General Operation