The parameters of the localization engine consists of the following:
active_mode
Selects whether localisation is switched off, or the position or measurement mode is selected.
Default value: off.
Position
This parameter enables the SmartPoint to perform RSS measurements for centralized
calculation. Only X,Y,Z and timestamp values are pushed.
Measurement
This parameter enables the SmartPoint to perform RSS measurements for centralized
calculation, debug or research purposes. The raw RSS measurements are pushed along
with the location (X,Y,Z, timestamp)
auto_period
This parameter represents the period in seconds in which the SmartPoint locates itself or
performs RSS measurements. Decreasing this parameter increases the energy consumption.
The minimum value of auto_period is set to 10 seconds.
Default value: 300.
discover_time
This parameter represents the time the Smartpoint searches for a 3000 Series network.
Default value: 32.
scan_time
This parameter represents the time the SmartPoint listens to MicroRouters for obtaining
RSSI information. Increasing this parameter increases the energy consumption of the
SmartPoint.
36/73 Ambient Systems B.V.
Illustration 20: Setting parameters of SmartPoint Localization Engine in Ambient Studio