is 11:1. Select whether only pushes, alerts or both message types have to be logged. This is
illustrated in Illustration 24.
Secondly, the flush functionality has to be configured. Select 0:System, 12:Logger and
1:SetFlushConfig for the same SmartPoint. Select direction 'oldest first', select logindex 0 and select
flush_push and flush_alert. This is illustrated in Illustration 25.
Third, flushing has to be enabled on the SmartPoint, this can be done by pressing the configure
driver button (of driver 0:System, 12:Logger). Select flush enable. The rate of flushing is defined as
M messages per period P, where M and P are adjustable at runtime. So each period P the flushing
mechanism will try to send at most M messages. For now the default values are M=1 and P=150. P is
expressed in seconds. If flushing is enabled for more than one function; F > 1, then P is divided by F
and in each sub period M messages from a single function are flushed. So effectively each function is
still flushed at rate M/P but the network load is spread over time per function. The configuration is
illustrated in Illustration 26.
42/73 Ambient Systems B.V.
Illustration 24: Setting the log driver