2.2.1 Display Console Layout
Figure 5
2.2.2 Sensor Operation Verification
Verify the indoor and outdoor humidity match closely with the console and sensor array in the same
location (about 5 to 10’ apart). The sensors should be within 10% (the accuracy is ± 5%). Allow
about 30 minutes for both sensors to stabilize. The humidity can be adjusted or calibrated later to
match each other a known source.
Verify the indoor and outdoor temperature match closely with the console and sensor array in the same
location (about 5 to 10’ apart). The sensors should be within 2°F (the accuracy is ± 1°F). Allow
about 30 minutes for both sensors to stabilize. The temperature can be adjusted or calibrated later to
match each other or a known source.
3 Remote Sensor Installation
It is recommended you mount the remote sensor on a north facing wall, in a shaded area. Direct
sunlight and radiant heat sources will result in inaccurate temperature readings. Although the sensor is
water resistant, it is best to mount in a well protected area, such as under an eve. Use a screw or nail
(not included) to affix the remote sensor to the wall, as shown in Figure 6.