User manual
Version 1.4 ©Copyright 2011, Ambient LLC. All Rights Reserved. Page 8
pressure (the pressure your location would be at if located at sea-level) is generally higher than your
measured pressure.
Thus, your absolute pressure may read 28.62 inHg (969 mb) at an altitude of 1000 feet (305 m), but
the relative pressure is 30.00 inHg (1016 mb).
The standard sea-level pressure is 29.92 in Hg (1013 mb). This is the average sea-level pressure
around the world. Relative pressure measurements greater than 29.92 inHg (1013 mb) are
considered high pressure and relative pressure measurements less than 29.92 inHg are considered low
pressure.
To determine the relative pressure for your location, locate an official reporting station near you (the
internet is the best source for real time barometer conditions, such as Weather.com or
Wunderground.com), and set your weather station to match the official reporting station.
To change the relative pressure when flashing, press the + key or - key to increase or decrease the
relative pressure setting to match the official reporting station.
4.3 Alarm Mode
4.3.1 Time Alarm
While in Normal Mode, press the ALARM key to activate or de-activate the alarm. If the alarm is
active, the alarm time will be displayed next to the alarm icon . If the alarm is de-active, OFF will
be displayed next to the alarm icon .
4.3.2 Setting the Time Alarm
To set the alarm time, press and hold the ALARM key for 3 seconds. The alarm hour will begin
flashing.
Change Alarm Hour. Press the + key or - key to adjust the alarm hour up or down.
Change Alarm Minute. Press the SET key again to set the alarm minute. Press the + key or - key to
adjust the alarm minute. Press the SET key again to exit the exit the
4.3.3 Cancelling the Alarm
When an alarm has been triggered, the alarm will sound and the alarm icon will flash for 120
seconds. Press the ALARM key to silence the alarm.
4.4 Min/Max Mode
While in Normal Mode, press the MIN/MAX key to enter the min/max mode.
Note: If you have multiple remote temperature and humidity sensors, select the Channel you wish
to view the min/max data before you enter the min/max mode.
1. Maximum Barometric Pressure. The maximum barometric pressure, associated date and
time, and the MAX icon will be displayed. To reset the maximum barometric pressure to the
current pressure, press and hold the MIN/MAX key for two seconds.
2. Minimum Barometric Pressure. Press the MIN/MAX key again. The minimum
barometric pressure, associated date and time, and the MIN icon will be displayed. To reset