User manual
Table Of Contents

Version 1.2 ©Copyright 2011, Ambient LLC. All Rights Reserved. Page 5
Note: The remote thermo-hygrometer will always display the un-calibrated humidity and is
unaffected by the calibrated humidity set from the display console.
4.2 Min/Max Mode
While in Normal Mode, press the MIN/MAX key to enter the minimum mode, and the MIN icon and
minimum records will be displayed at the bottom of the display. Press and hold the RESET key for
two seconds to reset the minimum values to the current values.
Press the MIN/MAX key to enter the maximum mode, and the MAX icon and maximum records will
be displayed. Press and hold the RESET key for two seconds or more to reset the maximum values to
the current values.
Press MIN/MAX key again to return the Normal Mode.
4.3 Multi-Channel Operation
The WS-0101 supports up to three WH2B remote thermo-hygrometers (one is included). The optional
sensors can be purchased at AmbientWeather.com.
4.3.1 Sensor Initialization
Power up the sensors and console in the following order:
1. Power up the console. Do not touch any of the buttons, as described in Section 2.4.
2. Power up the first remote thermo-hygrometer as described in Section 2.5. Wait until the
sensor reports into the console.
3. Power up the second remote thermo-hygrometer as described in Section 2.5. Wait until the
sensor reports to the console. The first sensor will be designated as Channel 1 and the second
sensor will be designated as Channel 2.
4. Power up the third remote thermo-hygrometer as described in Section 2.5. Wait until the
sensor reports to the console. The third sensor will be designated as Channel 3. The display
will switch between each sensor until you exit the initialization state by pressing any button.
4.3.2 Sensor Accuracy Note
Allow about one hour for all sensors to stabilize.
Verify the temperature values match closely with the console and sensor array in the same location
(about 10’ apart). The sensors should be within 4°F (the accuracy is ± 2°F).
Verify the humidity values match closely with the sensor array in the same location (about 10’ apart).
The sensors should be within 10% (the accuracy is ± 5%). Use the calibration procedure to remote
humidity inaccuracy.
4.3.3 Viewing the 3 Sensor Channels
To view the 3 sensor channels, select the CH/+ button. The minimum and maximum can be viewed
for each channel as specified in Section 4.2.
4.4 Humidity Calibration
Humidity measurement is among the more difficult problems in basic meteorology. Accuracy is
difficult to achieve and are subject to drift, so need regular recalibration.