User manual
Version 2.4 ©Copyright 2015, Ambient LLC. All Rights Reserved. Page 29
wind meter (available from Ambient Weather) and a constant speed, high speed fan.
6.13.4 Calibration Mode
While in the Normal Mode, press the ON/OFF key for 8 seconds to enter the calibration mode, and
the ADJ icon will be displayed. You can skip over any setting by selecting the enter key. To exit the
calibration mode at any time, select the history key
1. Wind Speed Calibration (default is 1.0, adjustment range 0.75 to 1.25). Press the up or
down key to increase or decrease the wind speed multiplier to match the calibrated source.
Press the ON/OFF key, and the value will return to the uncalibrated value.
2. Indoor Temperature Calibration. Press the enter key to calibrate the temperature in 0.1°C
(0.18 °F) increments. Press the up or down key to increase or decrease the temperature bias
to match the calibrated source. Press the ON/OFF key, and the value will return to the
uncalibrated value.
3. Indoor Humidity Calibration. Press the enter key to calibrate the humidity in 1%
increments. Press the up or down key to increase or decrease the humidity bias to match the
calibrated source. Press the ON/OFF key, and the value will return to the uncalibrated value.
4. Outdoor Temperature Calibration. Press the enter key to calibrate the temperature in 0.1°
increments. Press the up or down key to increase or decrease the temperature bias to match
the calibrated source. Press the ON/OFF key, and the value will return to the uncalibrated
value.
5. Outdoor Humidity Calibration. Press the enter key to calibrate the humidity in 1%
increments. Press the up or down key to increase or decrease the humidity bias to match the
calibrated source. Press the ON/OFF key, and the value will return to the uncalibrated value.
Press the enter key to exit the calibration mode.
Note: The dew point and wind chill are based on the calibration values.
6.14 Lost Sensor Resynchronization
If the signal is lost between the remote sensor (or transmitter) and the display console (or the receiver),
to resynchronize, while in normal mode, press and hold the down key for 5 seconds. The transmitter
search icon will appear.
Please wait several minutes for the search icon to turn off and the remote sensor reports in. Do not
touch any buttons until synchronization is complete.
6.15 Restoring to Factory Default
To restore the console to factory default, press and hold the up key for 30 seconds. The console will
beep and reset. Wait several minutes for the remote sensor to synchronize.