AMC XOi 4 ZONE 4 Local/4 Remote Mixed SOURCE DIGITAL H.O.H.
APPLICATION AND FEATURE LIST Features of the AMCTM model XOi * System for total 4 Zones * System with 8 Sources 4 Local / 4 Remote mixed Sources.
REAR PANEL CONNECTIONS/FRONT PANEL CONTROLS 8 1 2 Front 3 54 6 9 7 10 Rear Doorbells 1 & 2 Tel Lines 1 & 2 AMC PDM1 (Phone-Doorbell-Mute Module) Zone 1 Zone 2 Zone 3 Zone 4 7. 12VDC 8. Keypads & Remote Sources 9. Speaker Terminals 10. RS232 11. AC input receptacle with Fuse 1. Local Source Inputs 1~4 2. IR Out - 38KHz 3. IR Out - 56KHz 4. Mute 5. Link 6. Status FRONT PANEL 1 2 1. Power Switch (Standby / Off) & Blue LED 2.
REAR PANEL CONNECTIONS 1. Local Source Inputs 1~4 Each of these stereo RCA inputs receives an audio signal from up to four independent audio sources. Remarks: There are other 4 Remote sources from Zone 1~4 as Remote Source Inputs R5 to R8 can be selected by all zones. Remote Source R5 is located at XS1 of Zone 1, Remote Source R6 is located at XS1 of Zone 2, Remote Source R7 is located at XS1 of Zone 3 and Remote Source R8 is located at XS1 of Zone 4.
KEYPAD (XK1 for Zone 1 to 4) 6 BASS TREB 7 12 9 11 10 8 1 5 2 (JK2) TO XOi Rear Panel 4 or JK3 of Main XK1 3 1. LED's of Volume Level of the zone Volume-only one LED will be lighted up. (for energy saving purposes) 2. Volume up connected to the XS1 of Zone 1 to 4. (R5 located at Zone 1, R6 located at Zone 2, R7 located at Zone 3 and R8 located at Zone 4) The selected source button will remain lit. / down 3.
10. JK2 (RJ45) (TO XOi Rear Panel) Use Cat-5 cable to connect from the JK2 of XK1 to RJ45 of specific Zone on XOi Rear Panel (or JK3 of Main XK1 - option) JK3 of XK1 to JK2 of Another XK1. This is an option feature. 12. JK4 (RJ45) (To SUB ZONE) Use Cat-5 cable to connect from the JK4 of XK1 to main-in of amplifiers or power speakers. - This is an option feature. 11. JK3 (RJ45) (To Another XK1) Use Cat-5 cable to connect from the REMOTE SOURCE XS1 (for Zone 1 to 4) RCA Jack Inputs (L & R) 3.
REMOTE CONTROL 1 2 5 6 3 4 1. Power On & Off This button turns the zone on and off and powers all the zones off when it is pressed and held. Perform the same function as the volume button on the zone keypads. Th e vo lu me l ev el i nd ic at or o n th e keypad will respond correspondingly to the volume command from the remote control. 2.
INSTALLING THE XOi DIGITAL HOME SYSTEM 1. Prewire The XOi uses Cat-5 cable for keypad control and either two- or four-conductor 16gauge speaker wire. All the wire is homerun from each zone to the XOi. 2. The XOi digital home systems require Cat-5, unshielded, twisted pair (UTP), for communication between the keypads/display pads and the main XOi unit. Each end of the wire is terminated with an RJ45 connector. The XOi system can accommodate 500 total feet of Cat-5 cable for each zone.
Step-by-Step Crimping instructions Step1 Strip a 2 to 3 inches portion of the insulation, exposing the 4 twisted pairs. Step2 Untwist the wires and fan them out individually. Arrange the wires into the correct color scheme as shown in Fig.1 Step3 Flatten the wires in their correct order, and trim them evenly across the top. Most crimp tools have a wire trimmer built-in. It is best to trim the wires to about 1/2 in length.
4. Installing the XOi The XOi is designed to be placed on a shelf or in a component rack. If you are mounting the XOi with other components,you should remove the feet. The audio sources are plugged into the four local source inputs on the back panel of the XOi using stereo RCA cables, Fig.4 Source 1 Tuner 1 Audio Out 5.
6. Keypad XK1 and Zone Setup The Zone number each keypad XK1 belonging to is decided by which RJ45 connector each keypad connected through Cat-5 cable from JK2 of XK1 to XOi. EQ Control and Source Grouping The keypads can be used to set specific zone functions. These are for bass and treble EQ response and source grouping. To change bass response, press the BASS button . Adjust the bass level up or down by using the Volume Up and Volume Down buttons.
7. Using the Link Jack to create Eight Zones (This is an optional feature) Two XOi can be made to react as one using the back-panel 3.5mm connection labeled "Link". This requires the use of "Y" cables to link the source inputs and IR outputs. A single mono mini-patch cable is then plugged into the "Link" jack on both XOi. This links the All Off command so when it is initiated at any of the zone keypads, all eight zones will turn off. 8.
SPECIFICATIONS Total Zones . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Zones Zone 1~4 with Speaker Outputs . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15Wrms x 2 Sources . . . . . . . . . . . . . . . . . . . . . . . . . 4 Local / 4 Remote Mixed Sources Sensitivity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60mV IR outputs frequencies . . . . . . . . . . . . . . . . . . . .
SAFETY INSTRUCTION 1. READ INSTRUCTIONS 16. DAMAGE REQUIRING SERVICE All the safety and operating instructions should be read before the appliance is operated. 2. RETAIN INSTRUCTIONS The safety and operating instructions should be retained for future reference. 3. HEED WARNINGS All warnings on the appliance and in the operating instructions should be adhered to. 4. FOLLOW INSTRUCTIONS All operating and use instructions should be followed.
WELTRONICS CORP. LONDON/L.A. AMC Web: http://www.amchome.