Chapter 2. CLI Syntax Reference
66 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
group=3|4|5|6 indicates the number of disks per group for a RAID 50 type.
(This attribute can only be used when type=raid50.) Recall that a RAID 50 is
a multi-tier array. At the bottom-most layer, N number of disks per group are
used to form the RAID 5 layer. These RAID 5 arrays are then integrated into a
RAID 0. This attribute allows you to specify the number of disks in the RAID
5 level. Valid values are 3, 4, 5 and 6. For example group=3 indicates 3 disks
of RAID 5 at the bottom layer of RAID 50.
Note that a sufficient number of disks are required for a given pattern or disk
group. For example, given 6 disks, specifying 3 will create two RAID 5
arrays. With 12 disks, specifying 3 will create four RAID 5 arrays under the
RAID 0 level. With only 6 disks a grouping of 6 is not allowed, as you would
basically be creating a RAID 5.
The default RAID 50 grouping varies, based on number of disks. For 6 and 9
disks, default grouping is 3. For 8 disks, the default grouping is 4. For 10
disks, the default grouping is 5, and for 12 disks, the default grouping is 4. In
the case of 12, the disks could be grouped into groups of 3, 4, or 6 drives. A
grouping of 4 is set by default as it provides the best of net capacity and
performance.
Note that RAID-10 always has group=2, so an attribute specifying it’s group
is not necessary.
stripe=Stripe consists of the stripe size to be used. The following table
illustrates the supported and applicable stripes on unit types and controller
models. Stripe size units are in KB (kilobytes).
noscan attribute instructs CLI not to notify the operating system of the
creation of the new unit. By default CLI will inform the operating system.
One application of this feature is to prevent the operating system from
creating block special devices such as /dev/sdb and /dev/sdc as some
implementations might create naming fragmentation and a moving target.
nocache attribute instructs CLI to disable the write cache on the migrated
unit. Enabling write cache increases write performance at the cost of potential
data loss in case of sudden power loss (unless a BBU or UPS is installed). By
default the cache is enabled. To avoid the possibility of data loss in the event
of a sudden power loss, it is recommended not to set nocache unless there is a
BBU (battery backup unit) or UPS (uninterruptable power supply) installed..
Table 10: Supported Stripe Sizes
Model R0 R1 R5 R10 Spare Single
9K 16 N/A 16 16 N/A N/A
64 64 64
256 256 256