GB PARTS 1. Control panel 2. Air outlet 3. Handle 4. Casters 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Cord hanger 9. Water stopper (plug inside) 10. Foam extension 11. Foam with hole 12. Water tray 13. Hose adapter 14. Window/wall adapter 15. Cap 16. Exhaust hose 17. Water tube 18.
GB THANK YOU Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your air conditioner you should carefully read these instructions to maximise this product’s performance.
GB WARNING • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer, its service agent or a qualified person in order to avoid a hazard. • Any service other than regular cleaning or wick replacement should be performed by an authorized service representative. Failure to do so could result in a loss of warranty. POSITIONING This unit is portable and can easily be moved from one room to another.
GB • Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1). • Put the wall/window adapter (14) onto the exhaust hose (fig. 2). • Connect the hose with the rectangular end to the air conditioner (fig. 4). 1 2 16 3b 6 15 16 13 4 3a 14 5 Using the foam. Place the foam with the hole (11), if needed together with the foam extension (10), in the window and close this as far as possible to refrain the warm air from reentering the room (fig. 5).
GB OPERATION 1 5 4 3 2 1. ON/OFF Press the ON/OFF-button to switch the unit on or off. The unit selects the operating mode depending on the room temperature: - with an ambient temperature higher than 23 °C, cooling mode is selected - is the ambient temperature between 20 °C and 23 °C, then will fan mode be active. 2. Timer button Use this button to set a working time between 1 and 12 hours. The TIMER LED will be on. The unit switches off when the set time has run down. 3.
GB Remote control The air conditioner can be operated with the remote control. Two AAAbatteries are required to use the remote control. Point the remote control hand set towards the control panel of the unit and press the relevant button, the red LED on the hand set will flash whenever a button is pressed. Air flow a. Turn the roller to control the air flow direction of the vertical louvres. b. Move the air vent directly to adjust the air flow direction of the horizontal louvres.
GB PERMANENT DRAINAGE Switch off the unit and remove the plug from the mains. • • • • Remove the drain knob and the rubber plug. Connect the correct water tube onto the water outlet. Place the other end in a normal drain. Make sure that the tube is free from twists and bends. The tube must incline over its entire length. Dehumidification If the unit will be used mainly as dehumidification, do not connect the exhaust hose and let the warm air return in the room.
GB STORAGE See the instructions "Emptying the water container" on page 7. • Drain the condensed water completely. • Clean (or replace) the filter. • Put the unit on a sunny day in fan mode for a couple of hours to ensure that the inside becomes completely dry. • Store the power cable as shown, protect the unit against dust and store in a dry place not accessible for children. Cable storage TROUBLE SHOOTING Never try to repair or dismantle the air condition yourself.
GB TECHNICAL DATA Model BTU/h kW Cooling capacity Mains Power consumption Current Dehumidification Air delivery Recommended room size Refrigerant Compressor Fan speeds Thermostat Timer Dimensions (W x H x D) Weight W A L/24h m3/h m2 °C h mm kg AMC AMC AMC 7KE-410 10KE-410 12KE-410 6500 8300 9600 1.9 2.4 2.8 220–240 V / 50 Hz / 1Ph 690 830 1030 3 3.7 4.5 24 28.8 36 300 350 350 12 18 24 R410A rotary 2 18 – 32 1 – 12 377 x 750 x 400 29 30 32 Subject to modifications without prior notice.
Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc.
GB PARTS 5 1 2 6 3 7 8 9 4 1. Control panel 2. Air outlet 3. Handle 4. Casters 5. Air filter 6. Air inlet 7. Exhaust air outlet 8. Cord hanger 9. Water stopper (plug inside) 12 10 13 11 14 16 15 17 10. Foam extension 11. Foam with hole 12. Water tray 13. Hose adapter 2 14. Window/wall adapter 15. Cap 16. Exhaust hose 17.
GB THANK YOU Thank you for choosing this innovative Amcor air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your air conditioner you should carefully read these instructions to maximise this product’s performance.
4
GB POSITIONING This unit is portable and can easily be moved from one room to another. In doing so keep this in mind: • The air conditioner must stand upright on an even surface. • Position not (near) bath, douche or other wet or damp area. • Keep for free air circulation at least 50 cm free from any obstacle or curtains. 1 Installation • Put the exhaust hose into the round side of the exhaust hose adapter (13) (fig. 1). • Put the wall/window adapter (14) onto the exhaust hose (fig. 2).
GB OPERATION 1 3 2 3 2 4 1 ON/OFF and timer function Turn the control [1] to switch the unit on or off. When the unit is on, LED-1 is on. Timer function Use control [1] to set a working time between 1 and 8 hours. The unit switches off when the set time has run down. Mode selection and speed setting Select with control [2] the required operating mode cooling or fan mode. The corresponding LED (2 or 3) will lit. Select the larger symbol position for high or low fan speed, or low or strong cooling.
GB When the water container is full, the compressor and the ventilator stop functioning, LED [4] will lit. Switch off the unit and remove the plug from the mains. • Place the water tray flat on the floor under the drain. • Remove the drain knob. • Remove the rubber plug and fill the water tray then replace the plug to stop the water flow. Empty the tray and repeat this process until all water has been removed. • Replace the rubber plug and the drain knob, plug the unit in and switch on.
GB CLEANING First of all switch off the unit and pull the plug. Clean the housing with a soft, damp cloth. Never use aggressive chemicals, petrol, detergents or other cleansing solutions. Filter The single layer screen filter cleans the circulated air. The filter needs to be cleaned regularly with a vacuum cleaner to avoid blocking the air flow. • Push the two clips on the filter housing downward and pull the filter housing forward and out of the unit.
GB TROUBLE SHOOTING Never try to repair or dismantle the air conditioner yourself. Incompetent repairs result in loss of warranty and can endanger the user. Problem Cause Solution The unit does Check the plug fuse.
GB AMCOR GUARANTEE PROCEDURE Amcor products have a lower than industry norm failure rate, as we have strict quality control in our factory. However we are not 100% perfect and occasionally units can fail. When they do we have a simple returns procedure. All Amcor products are guaranteed for one-year from date of purchase, on a back to base principle. A copy of our guarantee page is attached. Consumers need to keep the till receipt as proof of purchase.
GB YOUR GUARANTEE DOMESTIC AIR CONDITIONERS If this product is found to be defective as a result of faulty materials or workmanship within one year from date of purchase, it will be repaired or replaced free of charge. This guarantee is subject to the following terms: Amcor Limited.
Hong Kong Amcor Ltd Suite 2007, Tower 6, The Gateway, Harbour City, 9 Canton Road, Tsim Sha Tsui, Kowloon, Hong Kong Tel: +852 2997 6865 Fax: +852 2997 6091 Email: amcorhk@amcorgroup.com United Kingdom Amcor Ltd 9 Ryan Drive, West Cross Centre, Great West Road, Brentford, Middlesex, TW8 9ER, United Kingdom Tel: +44 20 8560 4141 Fax: +44 20 8232 8814 Email: amcoruk@amcorgroup.com USA Amcor Inc.