Owner`s manual

SYSTEM INSTALLATION AND SERVICE
AT AND 3T STEAMERS
4211-103 10-10-11
Page 1
SYSTEM INSTALLATION AND SERVICE
AT AND 3T STEAMERS
WARNING
Electrical grounding is required
on all Steam Generators.
All electrical supplies should be
disconnected when servicing a
Steam Generator.
All wiring must be installed by a
licensed electrical contractor in
accordance with local and
national codes.
All plumbing must be installed
by a licensed plumber in
accordance with all applicable
local and national codes.
Generators are for indoor use only.
Generators are not for
space-heating purposes.
Be certain that steam bath
enclosures are properly sealed
to avoid water damage from
escaping steam. It is
recommended that 100%
silicone caulk be used to seal
all pipes and ttings. Steam
must be prevented from
escaping into the wall cavity.
Never shut off the water to an
appliance that is in use.
Electric Shock Hazard
High Voltage exists within this equipment.
There are no user serviceable parts
in this equipment.
REDUCE THE RISK OF
1. Exit immediately if uncomfortable, dizzy or sleepy. Staying too long in
a heated area is capable of causing overheating.
REDUCE THE RISK OF
Use care when entering or exiting the steam room, floor may be slippery.
NOTE: For additional safety instructions, see owner's manual.
CAUTION!
Do not contact steam head. Stay at least 12" away
from hot steam escaping from the steam outlet.
OVERHEATING AND SCALDING
2. Supervise children at all times.
3. Check with a doctor before use if pregnant, diabetic, in poor health or
under medical care.
4. Breathing heated air in conjunction with consumption of alcohol, drugs
or medication is capable of causing unconsciousness.
SLIPPING AND FALL INJURY
WARNING
4110-79
05-21-07
Amerec Steam Generators are listed by ETL. The generators come assembled and ready for installation. Check
that the size and rating of the generators are suitable for your application; refer to Steam Room Construction and
Generator Sizing Guide (Amerec document 4211-33).
Amerec AT and 3T Steam Systems consist of one AT or 3T generator acting as a “master” generator which may
control one or two other AT or 3T slaved generators. The sole purpose of ganging generators is to increase the
volume of steam generated without using multiple controls. The master generator controls the slaved generator(s)
through the cable(s) provided.
IMPORTANT
An exhaust fan installed outside the steam room is strongly recommended
to remove excess steam from the bathroom or shower area.
SECTION 1: GENERAL INFORMATION
(1) T100 Control plus
(2) or (3) AT or 3T
Steam generators
AMEREC STEAMBATH GENERATOR SYSTEMS
FOR USE WITH SYSTEMS INCORPORATING
ONE T100 CONTROL,
ONE AT OR 3T “MASTER” STEAM GENERATOR AND
ONE OR TWO AT OR 3T “SLAVED” GENERATOR(S)
STANDARD MODELS CONSIST OF
AT17 = AT 10 + AT7 + T100 CONTROL KIT
AT20 = AT 10 + AT10 + T100 CONTROL KIT
AT30 = AT 10 + (2) AT10s + T100 CONTROL KIT
3T20 = 3T 10 + 3T10 + T100 CONTROL KIT
3T24 = 3T 12 + 3T12 + T100 CONTROL KIT
3T28 = 3T 14 + 3T14 + T100 CONTROL KIT
3T36 = 3T 12 + (2) 3T10 + T100 CONTROL KIT
Other system con gurations may be available.
Contact technical support for further information: 1-800-363-0251
Save these instruction! Read all instructions carefully before installation!
POST ‘WARNING’ LABEL OUTSIDE STEAMBATH FOR SAFETY
WARNINGS! POSTING ON OR ADJACENT TO THE DOOR OF STEAM
ROOM IS REQUIRED FOR ALL COMMERCIAL INSTALLATIONS!