System Installation and Service Instructions
Page 19
SYMPTOMS PROBABLE CAUSES ACTION TO BE TAKEN
TABLE 2 Cont.
Master unit “ON”
Slave tank drained.
Slave unit won’t fill up.
Improper or no power supplied
or
No water Supplied
or
Plugged water solenoid valve
or
Water level probe is faulty
or
Burnt out heating elements
or
AG or 3G PCA is faulty
or
Slave control cable is faulty
or
AK or 3K in the Master unit is faulty.
1.a. Make sure the circuit breaker to the Slave unit is “ON”.
b. Using a voltmeter, check the voltage across the two fuses on the
Slave PAL. Voltage should be 208/240V.
c. Check fuses on the Slave PAL. If fuse(s) are blown, replace with
equivalent fuse. If the fuse blows again- Call Steam Technical Support.
2. Check for proper water supply (supply valve “ON”). Check for drain
valve close.
3. Remove the blue wire from the level probe. If the unit fills,, clean or
replace the level probe.
4. Reconnect the blue wire to the shortest level probe. At the water
valve solenoid, slide back the red connector enough to get the voltmeter
probes on the solenoid terminals. Measure the voltage across the
solenoid terminals. If it is not 208/240V, replace the PCA. If 208/240V is
found, proceed with steps 5 & 6.
5. Remove water solenoid valve: disassemble, clean, reassemble and
check for proper operation.
6. Replace the water solenoid valve.
7. Call AMEREC Service Department.
Water continually sputters out of
any steam head.
Foaming contaminants in the
water supply.
1. Flush tank 3 times. See Section 8: FLUSHING PROCEDURE.
2. Call Steam Technical Support.