1634781 - Fire Extinguisher (B456, B417, B500, A411) Revision Date 15-Apr-2021
Personal precautions, protective equipment and emergency procedures
Personal precautions
Contents under pressure. Empty containers pose a potential fire and explosion hazard. Do
not cut, puncture of weld containers. Ensure adequate ventilation. Use personal protective
equipment as required. Evacuate personnel to safe areas. Do not breathe
dust/fume/gas/mist/vapors/spray. Do not puncture or incinerate cans.
Other Information
Refer to protective measures listed in Sections 7 and 8.
Methods and material for containment and cleaning up
Methods for containment
Prevent further leakage or spillage if safe to do so. Keep out of drains, sewers, ditches and
waterways.
Methods for cleaning up
Avoid breathing dust or spray mist. Pick up and transfer to properly labeled containers.
7. HANDLING AND STORAGE
Precautions for safe handling
Advice on safe handling
Handle in accordance with good industrial hygiene and safety practice. Contents under
pressure. Empty containers pose a potential fire and explosion hazard. Do not cut, puncture
of weld containers. Avoid contact with skin, eyes or clothing. Ensure adequate ventilation.
Do not breathe dust/fume/gas/mist/vapors/spray. Do not puncture or incinerate cans. Do
not eat, drink or smoke when using this product.
Conditions for safe storage, including any incompatibilities
Storage Conditions
Keep containers tightly closed in a dry, cool and well-ventilated place. Protect from sunlight.
8. EXPOSURE CONTROLS/PERSONAL PROTECTION
Control parameters
Exposure Limits
The following ingredients are the only ingredients of the product above the cut-off level (or
level that contributes to the hazard classification of the mixture) which have an exposure
limit applicable in the region for which this safety data sheet is intended or other
recommended limit. At this time, the other relevant constituents have no known exposure
limits from the sources listed here.
Chemical name ACGIH TLV OSHA PEL NIOSH IDLH
Attapulgite
12174-11-7
TWA: 1 mg/m
3
respirable
particulate matter
-
Chemical name Alberta British Columbia Ontario TWAEV Quebec
Attapulgite
12174-11-7
TWA: 1.0 mg/m
3
TWA: 1 mg/m
3
TWA: 1 fibre/cm3
Other Exposure Guidelines
See section 15 for national exposure control parameters.
Appropriate engineering controls
Engineering controls
Showers
Eyewash stations
Ventilation systems.
_____________________________________________________________________________________________