Specifications

Q-D1 CONTROLS AND FEATURES
1. MASTER VOLUME CONTROL - This rotary knob is used to control the master output level (volume).
To avoid distorted output try to maintain an average output signal level +4 dB. Be sure this volume
control is always set to zero before turning the unit on.
2. MIC LEVEL - This rotary knob is used to control the microphone volume output level. Turning the
knob in a clockwise direction will increase volume output.
3. CHANNEL BASS CONTROL - This knob is used to adjust the low frequency levels of a channel
allowing for a maximum bass gain of 12dB or maximum signal decrease of -26dB. Turning the knob
in a counter-clockwise direction will decrease the amount of bass applied to a channel signal, turning
the knob in a clockwise direction will increase the amount of bass applied to a channel signal.
4. CUE MIXING CONTROLLER - This switch selects the channel for monitoring. The monitor signal
comes from the Prefader. This means it will not be affected by the channel faders. You can monitor
each channel individually. Connect your headphones to the HEADPHONES jack. Flip the CUE MIXING
CONTROL switch to channel you wish to monitor. If the CUE MIXING CONTROL is set to the center
position, you can monitor both the channels at once.
5. “Q” START ON/OFF
- This function works in conjunction with a compatible American Audio® "Q"
Top Panel
©American Audio® - www.AmericanAudio.us - Q-D1™ Instruction Manual Page 8
1
11
10
9
8
13
5
4
3
2
12
7 6