CC-RELATIVE (ENC)
Control Change messages are status 0xBn, where n is the channel for the specified CC
controller. Thus, the controller MIDI ID is indicated with the channel along with the CC
number. The value 0x40 indicates the change in the controller. This is an offset to 0x40
“one’s complement” notation.A message with data 0x43 indicates a positive change of 3. A
message with data 0x31 indicates a negative change of 15.
SWITCH ON/OFF (SW, CENTER, CW, CCW)
These messages are used for switches. Control Change messages are sent with status 0x9n,
SWITCH On and Off values are 0x7F and 0x00, where n is the channel.
LED ON/OFF (LED)
These messages are used for LEDs .Control Change messages are sent with status 0x9n, LED
On and Off values are 0x7F and 0x00, where n is the channel.
PITCH BEND
Pitch Bend messages are status 0xEn, where n is the channel for the specified controller.
Thus, the controller ID is indicated only by the channel. For accurate changes, the 14 bit data
in a pitch bend message is reserved for absolute controllers which require more than 7 bits
of data.
LEVEL LED (LEVEL)
These messages are used for LEVEL LEDs. Control Change messages are sent with status
0x9n, LED Off value is 0x00 and On value is related to LED amount, 0x01 with one LED, 0x02
with two LEDs…., where n is the channel.