Florida Building Code Approved Fastener Chart
This fastener schedule is provided as an example of fastening requirements.
Requirements may vary by product, building type, application and region. Contact your
local building code ofcial for requirements in your area.
Application Anchor Type Anchor Size
Minimum
Embedment
Minimum
Clearance to
Masonry Edge
Minimum
Clearance to
Adjacent Anchor
1X Buck or
Masonry Frame
ITW 1/4" 1–1/4" 2–1/2" 3"
1X Buck or
Masonry Frame
ELCO 1/4" 1–1/4" 1" 4"