Specifications

American DJ® - www.americandj.com - Accu UFO PRO Instruction Manual Page 34American DJ® - www.americandj.com - Accu UFO PRO Instruction Manual Page 33
Accu UFO PRO Editing Program
Editing procedure 3: Record the selected scenes automati-
cally from external controller:
1. Access the main menu.
2. Select “EDIT” by pressing the UP or DOWN buttons, press
ENTER.
3. Press the UP button until the display shows “STEP”, press
ENTER.
4. Now adjust and set the number of steps by pressing the
UP or DOWN buttons. Press ENTER to conrm the number of
steps, and “PASS” will display briey.
5. Now press the DOWN button until “REC” is displayed, and
press ENTER.
6. The display will now show “RE.XX”, “XX” stands for the scene
number in the internal memory which the scenes from the con-
troller will be stored to. Press ENTER when you have chosen
the scene number.
7. Call up the scenes on the controller, and the xture will
record the scenes from the controller automatically. After the
number of scenes as selected in the “STEP” menu are loaded
into the xture, it will stop the procedure and return to the pre-
vious menu.
8. Press MODE/ESC to exit the “EDIT” menu and return to the
main menu.
Accu UFO PRO Error Codes
When power is applied, the unit will automatically enter a
“reset/test” mode. This mode brings all the internal motors to a
home position. If there is an internal problem with one or more
of the motors an error code will ash in the display in the form
of “XXer”, “XX” will represent a function number. For example,
when the display shows “03Er,” it means there is some type of
error with the channel 3 motor. If there are multiple errors during
the start-up process they will all ash in the display. For exam-
ple: if the xtures has errors on channel 1 and channel 3 all at
the same time, you will see the error message ash “01Er”, and
“03Er repeated 5 times.
If an error does occur during the initial start-up procedure the
xture will self-generate a second reset signal and try to realign
all the motors and correct the errors, if the errors persist after a
second attempt a third attempt will be made.
If after a third attempt all the errors have not been corrected the
xture will make the following determinations:
1) 3 or more errors - The xture cannot function properly with
three or more errors therefore the xture will place itself in a
stand-by mode until subsequent repairs can be made.
2) Less than 3 errors - If the xture has less than 3 errors, there-
fore most other functions will work properly. The xture will
attempt to operate normally until the errors can be corrected by
a technician. The errors in question will remain ashing in the
display as a reminder of internal errors.
01Er – PAN movement error:
This message will appear after a xture reset, if the pan-yoke’s
magnetic-indexing circuit malfunctions (sensor failed or magnet
is missing) or there is a stepper motor failure (defective motor
or a defective motor IC drive on the main PCB).
03Er – TILT movement error:
This message will appear after a xture reset, if the tilt mag-
netic-indexing circuit malfunctions (sensor failed or magnet is